Critical assessment of hexavalent chromium species from different solid environmental, industrial and food matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
17
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 127 publications
0
17
0
Order By: Relevance
“…For elution of the Cr species, anion exchange chromatography was used with (NH 4 ) 2 SO 4 (0.25 M) + NH 4 OH (0.1 M) as the mobile phase at a constant flow rate of 0.4 mL/min. Figure A shows the separation of Cr(III) and Cr(VI) in water, and Figure B shows the same separation in AES; the absence of Cr(III) in AES confirmed that, in the presence of a strong alkaline environment, Cr(III) remained in the solid phase . The accuracy of the EPA 3060A method was evaluated by analysing 2 different recovery samples produced in the laboratory.…”
Section: Resultsmentioning
confidence: 96%
See 3 more Smart Citations
“…For elution of the Cr species, anion exchange chromatography was used with (NH 4 ) 2 SO 4 (0.25 M) + NH 4 OH (0.1 M) as the mobile phase at a constant flow rate of 0.4 mL/min. Figure A shows the separation of Cr(III) and Cr(VI) in water, and Figure B shows the same separation in AES; the absence of Cr(III) in AES confirmed that, in the presence of a strong alkaline environment, Cr(III) remained in the solid phase . The accuracy of the EPA 3060A method was evaluated by analysing 2 different recovery samples produced in the laboratory.…”
Section: Resultsmentioning
confidence: 96%
“…Figure 1A shows the separation of Cr(III) and Cr(VI) in water, and Figure 1B shows the same separation in AES; the absence of Cr(III) in AES confirmed that, in the presence of a strong alkaline environment, Cr(III) remained in the solid phase. 17 The accuracy of the EPA 3060A method was evaluated by analysing 2 different recovery samples produced in the laboratory. The first sample was prepared by adding the soil-based NIST SRM 2701 with a certified content of Cr(VI) to a face powder cosmetic sample.…”
Section: Methods Performancesmentioning
confidence: 98%
See 2 more Smart Citations
“…As the chromium species content in such samples is rather low, the coupling of liquid chromatography with inductively coupled plasma mass spectrometry (HPLC–ICP-MS) is a most often used technique, which is based on the combination of a separation method with an element-selective detection system [ 28 ]. Anion exchange columns and columns, which have both anion and cation exchange capabilities, are especially used for chromium speciation analysis [ 29 ]. High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) is often used in analyses of different environmental matrices such as natural water, soils, sediments, etc.…”
Section: Introductionmentioning
confidence: 99%