2022
DOI: 10.1016/j.ijom.2021.08.027
|View full text |Cite
|
Sign up to set email alerts
|

Critical appraisal of patient-specific implants for secondary post-traumatic orbital reconstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 45 publications
(69 reference statements)
0
2
0
Order By: Relevance
“…This overview is not comprehensive, and novel design options are regularly introduced in the literature. Posterior to bulbus [49] Orbital floor elevated in sagittal relation Amount [22] Based on clinical findings, advanced diagnostics [38] Slight overcorrection [50] Eccentric screw alters implant position [47] Fix implant if form stable [40] Fixation re-use Accuracy Re-used screw hole [54] Only in secondary reconstruction Multi-piece Positioning, stability, Lazy-S [42,47,49] accuracy Interlocking [46,48,55,56] Design considerations can be categorized based on their intended effect: stability, positioning ease, accuracy of implant positioning or alleviation of clinical symptoms. The size and shape of the implant are dependent on the extent of the defect.…”
Section: Patient-specific Implant Designmentioning
confidence: 99%
See 2 more Smart Citations
“…This overview is not comprehensive, and novel design options are regularly introduced in the literature. Posterior to bulbus [49] Orbital floor elevated in sagittal relation Amount [22] Based on clinical findings, advanced diagnostics [38] Slight overcorrection [50] Eccentric screw alters implant position [47] Fix implant if form stable [40] Fixation re-use Accuracy Re-used screw hole [54] Only in secondary reconstruction Multi-piece Positioning, stability, Lazy-S [42,47,49] accuracy Interlocking [46,48,55,56] Design considerations can be categorized based on their intended effect: stability, positioning ease, accuracy of implant positioning or alleviation of clinical symptoms. The size and shape of the implant are dependent on the extent of the defect.…”
Section: Patient-specific Implant Designmentioning
confidence: 99%
“…Support on existing bony structures is taken into account to ensure the stability of the reconstruction. Analogous to the preformed implants, support is most often found at three points in the orbit [22,38]. Fixation is recommended to ensure a stable position of the PSI [39,40].…”
Section: Patient-specific Implant Designmentioning
confidence: 99%
See 1 more Smart Citation
“…Schreurs et al demonstrated improved postoperative outcomes in enophthalmos, diplopia, and hypoglobus with the use of PSIs. 27 Custom-made implants in delayed cases can be helpful in providing a patient-specific volumetric repair of the orbital fractures and to correct enophthalmos. However, timing in creation of custom-made implants can be variable and potentially costly.…”
Section: Surgical Managementmentioning
confidence: 99%
“…Flat implants, however, might not be appropriate in circumstances where the orbital walls are depressed or have uneven forms. (17,18) The intricate and complex 3D morphologies with restricted intraoperative vision and no conventional implant fixation site make reconstructing complex orbital fractures involving numerous wall fractures with posterior edge and inferior orbital rim abnormalities difficult. Because titanium mesh can be fixed rigidly with screws, so it is the implant which is of choice in this scenario.…”
Section: Introductionmentioning
confidence: 99%