Criterion-Related Validity of a Clinical Measure of Dorsal First Ray Mobility

Abstract: Study Design: Test-retest methodological design using a sample of convenience. Objective: To determine the criterion-related validity and the reliability of measuring first ray mobility with a ruler. Background: Studies have questioned the accuracy of assessing first ray mobility by manual examination. Use of a ruler and adherence to strict guidelines in positioning of the patient may improve the measure. This study investigates the validity, and the intrarater and interrater reliability of measuring dorsal fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
30
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(32 citation statements)
references
References 13 publications
2
30
0
Order By: Relevance
“…This device produces a force displacement measurement, and records movement from a probe placed on the head of the first metatarsal. In spite of these instruments having been used in various studies, [11][12][13][14][15][16] they have some inconveniences such as, for example, being too complex, being large, not quantifying plantarflexion (which would be useful to compare with dorsiflexion), or not reflecting the combined movements of dorsiflexion-inversion and plantarflexion-eversion [4,17]. These are possible reasons why they are not used in daily clinical practice [8].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This device produces a force displacement measurement, and records movement from a probe placed on the head of the first metatarsal. In spite of these instruments having been used in various studies, [11][12][13][14][15][16] they have some inconveniences such as, for example, being too complex, being large, not quantifying plantarflexion (which would be useful to compare with dorsiflexion), or not reflecting the combined movements of dorsiflexion-inversion and plantarflexion-eversion [4,17]. These are possible reasons why they are not used in daily clinical practice [8].…”
Section: Introductionmentioning
confidence: 99%
“…More simple instruments have been subsequently created aiming at solving some of the aforementioned inconveniences [18,19]. However, some studies have reported only limited concordance and data reliability [16,20].…”
Section: Introductionmentioning
confidence: 99%
“…The examiner (WMG) is a physical therapist by training and has a 20-year history of translating research into practice [15,24]. The measures of foot mobility are listed, with the baseline recorded in sitting:…”
Section: Clinical Measurement Proceduresmentioning
confidence: 99%
“…Symptoms related to the sesamoids may manifest as plantar pain and localized tenderness to palpation. Custom devices have been developed to objectively quantify 1 st ray dorsal mobility [69, 70] and 1 st metatarso-phalangeal joint mobility [71] in in vivo research studies; however these devices are not in widespread use in clinical practice.…”
Section: Foot Painmentioning
confidence: 99%