2008
DOI: 10.1159/000117635
|View full text |Cite
|
Sign up to set email alerts
|

Creation of Ventricular Septal Defects on the Beating Heart in a New Pig Model

Abstract: Background/Aims: So far, surgical and interventional therapies for muscular ventricular septal defects (mVSDs) beyond the moderator band have had their limitations. Thus, alternative therapeutic strategies should be developed. We present a new animal model for the evaluation of such strategies. Methods: In a pig model (n = 9), anterolateral thoracotomy was performed for exposure of the left ventricle. mVSDs were created under two- and three-dimensional echocardiography with a 7.5-mm sharp punch instrument, whi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…In short-term porcine model, we demonstrated the general feasibility of this technique. 16 In this study, we report our results on the evaluation of this technique in a long-term porcine model in which residual shunting, development of LV dysfunction, and integration of the patch into the septum were especially addressed.…”
Section: Abbreviations and Acronymsmentioning
confidence: 99%
See 2 more Smart Citations
“…In short-term porcine model, we demonstrated the general feasibility of this technique. 16 In this study, we report our results on the evaluation of this technique in a long-term porcine model in which residual shunting, development of LV dysfunction, and integration of the patch into the septum were especially addressed.…”
Section: Abbreviations and Acronymsmentioning
confidence: 99%
“…Anesthesia and surgical preparation were performed as described previously. 14,16 Briefly, the right-sided carotid artery and jugular vein were surgically exposed, and the artery was cannulated with a 9F introducer sheath and the vein with an 11F introducer sheath. Arterial pressure and central venous pressure were measured continuously.…”
Section: Anesthesia and Surgical Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Anesthesia and surgical preparation was performed as described before [22]. Shortly, the animals were put on the ventilator and anesthetized with propofol (induction 1.5–2 mg/kg BW), maintenance 10 mg/kg BW/h; Fresenius Kabi, Bad Homburg, Germany), and fentanyl (induction 0.02 mg/kg BW, maintenance 0.045 mg/kg BW/h, DeltaSelect, Dreieich, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…Creation of mVSDs was carried out under two‐dimensional (2D) guidance as described previously [22]. For 2D echocardiography (Sonos 5500, Philips Healthcare, Eindhoven, Netherlands), a 5 MHz transesophageal echocardiographic probe was placed behind the heart via an additional incision.…”
Section: Methodsmentioning
confidence: 99%