2007
DOI: 10.1166/sl.2007.209
|View full text |Cite
|
Sign up to set email alerts
|

Cr(III) Ion-Selective Membrane Sensor Based on 1,3-Diamino-2-Hydroxypropane-N,N,N′,N′ Tetraacetic Acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 56 publications
(18 citation statements)
references
References 0 publications
0
18
0
Order By: Relevance
“…In order to find selectivity behavior of H 2 Me 2 bpb toward cations, its interaction with lanthanide ions and other common mono, di and tri valent ions were investigated conductometrically in an acetonitrile solution by previously describe method [32][33][34][35]. The complex formation constant, K f , shows the selectivity of the used ionophore toward Ho 3+ ions (K f : 5.6×10 6 ) among the all other cations tested.…”
Section: Potential Responses Of the Ho 3+ Sensormentioning
confidence: 99%
“…In order to find selectivity behavior of H 2 Me 2 bpb toward cations, its interaction with lanthanide ions and other common mono, di and tri valent ions were investigated conductometrically in an acetonitrile solution by previously describe method [32][33][34][35]. The complex formation constant, K f , shows the selectivity of the used ionophore toward Ho 3+ ions (K f : 5.6×10 6 ) among the all other cations tested.…”
Section: Potential Responses Of the Ho 3+ Sensormentioning
confidence: 99%
“…A Pyrex tube (3-5 mm o.d. on top) was dipped into the mixture for about 5 s, so that the formation of a transparent membrane (about 0.3 mm thickness) could be achieved (Behmadi et al 2007;Pooyamanesh et al 2007;Shokrollahi et al 2007;Ganjali, Moghaddam et al 2006;Zamani, Abedini-Torghabeh, and Ganjali 2006;Zamani, Rajabzadeh, and Ganjali 2006b;Abedi et al 2007;Zamani, Ganjali, and Adib 2007b;Saleh, Soliman et al 2006;Ganjali, Dodangeh et al 2006;Ganjali et al 2007;Zamani, Ganjali, Norouzi, Meghdadi 2008b;Norouzi, Adib, Rezapour, and Accedy 2005;. Then, the tube was removed from the mixture, kept at room temperature for 12 h, and filled with an internal solution (1.0 Â 10 À3 M SrCl 2 ).…”
Section: Electrode Preparationmentioning
confidence: 99%
“…A Pyrex tube (3-5 mm o.d.) was dipped into the mixture for about 10 s, in order to attain the transparent membrane formation of about 0.3 mm in thickness (Behmadi et al 2007;Pooyamanesh et al 2007;Ganjali et al 2006a;Ganjali et al 2003;Shokrollahi et al 2007;Ganjali et al 2006b;Zamani et al 2005a;Zamani et al 2005b;Zamani et al 2008a;Zamani et al 2006d;Abedi et al 2007;Zamani et al 2007f;Saleh et al 2006a;Ganjali et al 2006c;Saleh et al 2006b;Ganjali et al 2005a;Ganjali et al 2005b;Zamani et al 2008b). In the end, the tube was removed from the solution, kept at room temperature for 12 h, and filled with an internal filling solution (1.0 Â 10 À3 M Ba(NO 3 ) 2 ).…”
Section: Electrode Preparationmentioning
confidence: 99%