2020
DOI: 10.1007/s10544-020-00495-3
|View full text |Cite
|
Sign up to set email alerts
|

Covalent immobilization of luminescent oxygen indicators reduces cytotoxicity

Abstract: Luminescence-based oxygen sensing is a widely used tool in cell culture applications. In a typical configuration, the luminescent oxygen indicators are embedded in a solid, oxygen-permeable matrix in contact with the culture medium. However, in sensitive cell cultures even minimal leaching of the potentially cytotoxic indicators can become an issue. One way to prevent the leaching is to immobilize the indicators covalently into the supporting matrix. In this paper, we report on a method where platinum(II)-5,10… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 47 publications
(53 reference statements)
1
6
0
Order By: Relevance
“…The decrease in cardiomyocyte beating frequency during ischemic stress has been earlier reported in primary CMs from rat 27 29 , in perfused whole mouse heart 30 . We and others have also reported the decrease with pluripotent stem cell derived-CMs 11 , 12 , 24 , 31 , as well as the increase in the beating frequency upon reoxygenation 11 , 12 , 24 , 27 , 29 31 .…”
Section: Discussionsupporting
confidence: 65%
See 4 more Smart Citations
“…The decrease in cardiomyocyte beating frequency during ischemic stress has been earlier reported in primary CMs from rat 27 29 , in perfused whole mouse heart 30 . We and others have also reported the decrease with pluripotent stem cell derived-CMs 11 , 12 , 24 , 31 , as well as the increase in the beating frequency upon reoxygenation 11 , 12 , 24 , 27 , 29 31 .…”
Section: Discussionsupporting
confidence: 65%
“…The partial pressure of oxygen (pO 2 ) was measured from one sample to verify that the oxygen dynamics in the cell culture were as expected. In the verification experiment, a luminescence-based sensor together with a highly biocompatible sensing material, developed by Välimäki and coworkers 24 was used to monitor the oxygen level in the culture. The pO 2 was measured once a minute during the entire experiment, while MEA signals were recorded for 1 min every 30 min throughout the experiment at 20 kHz sampling frequency.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations