2016
DOI: 10.1016/j.applthermaleng.2016.06.033
|View full text |Cite
|
Sign up to set email alerts
|

Coupling performance analysis of a solar aided coal-fired power plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(13 citation statements)
references
References 25 publications
0
12
0
Order By: Relevance
“…Hu et al 2,11 reported the energy advantages and exergy advantages of a SAPG system based on a typical 500 MWe brown coal-fired power generation unit. Li et al 16 carried out the coupling performance analysis of a SAPG system by the proposed all-condition mechanism model. Yang et al 13 demonstrated the advantages of SAPG technology based on a 200 MWe coal-fired thermal power plant in terms of solar to power efficiency, specific fuel and steam consumption rates, under various integration scenarios.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Hu et al 2,11 reported the energy advantages and exergy advantages of a SAPG system based on a typical 500 MWe brown coal-fired power generation unit. Li et al 16 carried out the coupling performance analysis of a SAPG system by the proposed all-condition mechanism model. Yang et al 13 demonstrated the advantages of SAPG technology based on a 200 MWe coal-fired thermal power plant in terms of solar to power efficiency, specific fuel and steam consumption rates, under various integration scenarios.…”
Section: Introductionmentioning
confidence: 99%
“…Zhai et al 15 carried out the life cycle assessment of solar-aided coal-fired power system, based on the grey relation analysis, they found that the SAPG system with thermal storage system was better than that of the coal-fired power system and the SAPG system without thermal storage system. Li et al 16 carried out the coupling performance analysis of a SAPG system by the proposed all-condition mechanism model. Zhang et al 17 analyzed the performance of a SAPG system by two integration schemes based on a practical 660 MWe supercritical power generating unit and the results showed that the standard coal consumption rate of power generation could be decreased by more than 17 g/kWh.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Yang et al considered a 200 MWe coal-fired unit as an example and investigated four different integration schemes, and the results show that the solar thermal to power efficiency can be over 36% for the solar heat at 260 ℃ [9]. Then, the thermal performance [6,[10][11][12][13], economic performance [14,15] and off-design performance [5,6,16] different modes of solar aided coal-fired power generation system through theoretical calculations [23]. These studies indicated that SACP system is a promising way for the large scale utilisation of solar energy with high efficiency and can reduce the fossil fuel load in the coal-fired power system.…”
Section: Introductionmentioning
confidence: 99%
“…Air pollution and global warming have been posing a serious threat to human health and the environment, which is mainly caused by the use of fossil fuel. In China, over 70% of the electrical demand is met by coal-fired power generation stations [1,2], which contributes a large proportion of greenhouse gas and pollution emissions. In this matter, the Chinese government has taken effective emergency measures in order to address these problems.…”
Section: Introductionmentioning
confidence: 99%