1980
DOI: 10.1021/ac50064a056
|View full text |Cite
|
Sign up to set email alerts
|

Coupling of capillary gas chromatograph and Fourier transform mass spectrometer

Abstract: White, R. L.; Ledford, E. B., Jr.; Ghaderi, S.; Wilkins, C. L.; Gross, M. L. Anal. Chem. 1980, 52, 1525-1527. McIver. R. T., Jr.: Ledford, E. B., Jr.; Miiier, J . S. Anal. Chem. 1975. 47, 692. Ghaderi, S.; Wilkins, C. L.; Gross, M. L.. submitted for publication in Anal. Chem . Ghaderi, S.; Ledford, E. B., Jr.; Gross, M. L.; Wilkins. C . L.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
25
0

Year Published

1983
1983
2020
2020

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 53 publications
(28 citation statements)
references
References 11 publications
2
25
0
Order By: Relevance
“…While prior studies have described the coupling of chromatographic separations with electron impact sources (e.g., GC-EI-TOF-MS, 38 GC-EI-QLT-Orbitrap, 39 and GC-EI-FT-ICR MS 40,41 ), more recently, the GC and LC coupling to API-FT-ICR MS has shown advantages for the detection of molecular components and the separation of isomeric components (e.g., GC-APCI-FT-ICR MS, 15,42 and HPLC-ESI/APCI/APPI/APLI-FT-ICR MS 43,44 ).…”
Section: Introductionmentioning
confidence: 99%
“…While prior studies have described the coupling of chromatographic separations with electron impact sources (e.g., GC-EI-TOF-MS, 38 GC-EI-QLT-Orbitrap, 39 and GC-EI-FT-ICR MS 40,41 ), more recently, the GC and LC coupling to API-FT-ICR MS has shown advantages for the detection of molecular components and the separation of isomeric components (e.g., GC-APCI-FT-ICR MS, 15,42 and HPLC-ESI/APCI/APPI/APLI-FT-ICR MS 43,44 ).…”
Section: Introductionmentioning
confidence: 99%
“…The first successful coupling of an FTMS and a capillary column gas chromatograph was achieved in 1980 (35) and elaborated and then linked with Fourier transform infrared in 1982 (36,37). It has been proposed that FTMS is well suited for high-resolution multiple ion monitoring (35). The obstacle for high resolution in the GC-MS mode is the high pressure in the trap, which results from admitting GC eluent and carrier gas.…”
Section: Sample Introduction and Ionizationmentioning
confidence: 99%
“…The FT-ICR mass spectrometer was custom-built for analytical method development [27] and consisted of a 1.2-tesla Varian electromagnet, a 4.76-cm cell, and either a Nicolet 2000 (Madison, WI) or a MIDAS ( M odular I CR D ata A cquisition S ystem, National High Magnetic Field Lab, Florida State University) data system. The MIDAS system consisted of a FT-ICR cell controller, an electron-gun controller, and a PC running MIDAS software, version 3.18.…”
Section: Methodsmentioning
confidence: 99%