2015
DOI: 10.1063/1.4927716
|View full text |Cite
|
Sign up to set email alerts
|

Coupling an electrospray source and a solids probe/chemical ionization source to a selected ion flow tube apparatus

Abstract: A new ion source region has been constructed and attached to a variable temperature selected ion flow tube. The source features the capabilities of electron impact, chemical ionization, a solids probe, and electrospray ionization. The performance of the instrument is demonstrated through a series of reactions from ions created in each of the new source regions. The chemical ionization source is able to create H3O(+), but not as efficiently as similar sources with larger apertures. The ability of this source to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Recently, Viggiano and co-workers reported a new ESI source, designed by Ardara Corp., for their SIFT . Our ESI design utilizes an ion funnel and is similar to that developed for guided-ion beam experiments. , A schematic of our ESI source is shown in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…Recently, Viggiano and co-workers reported a new ESI source, designed by Ardara Corp., for their SIFT . Our ESI design utilizes an ion funnel and is similar to that developed for guided-ion beam experiments. , A schematic of our ESI source is shown in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…The upstream end of the instrument 21 has gone through an even bigger upgrade. In order to make it easier to change sources, a quadrupole bender (F) allows three ions sources to be attached simultaneously.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Thermal kinetic measurements were performed on a variable temperature selected ion flow tube (VT-SIFT) at the Air Force Research Laboratory, described in detail previously. , Sm + was formed using a glow discharge rod source, similar to that described above, and detailed elsewhere . Briefly, approximately 1 std L min –1 of a 10:1 He to Ar gas mix at a pressure of approximately 1 Torr flowed over an iron “boat” containing Sm chips.…”
Section: Experimental and Theoretical Methodsmentioning
confidence: 99%