2022
DOI: 10.1016/j.apgeochem.2022.105413
|View full text |Cite
|
Sign up to set email alerts
|

Coupled dynamics of aqueous biogeochemistry in contrasting floodplain environments: Implications for Critical Zone carbon sequestration along redox gradients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0
2

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 77 publications
1
6
0
2
Order By: Relevance
“…critical zone, Fe-cycling bacteria, microbial population, redox gradients, riparian sediments and narrow slope, whereas the west bank is adjacent to a flat and wide floodplain. The soil profile consists of post-colonial oxic deposits, pre-colonial anoxic buried wetland soils underlain by suboxic valley-bottom gravel (Lazareva et al, 2022;Sawyer et al, 2014;Walter & Merritts, 2008). Soil pore water was collected by in situ borosilicate glass samplers (50 mm long, 20 mm diameter, 1 μm pore size; Ecotech) with attached PTFE (Teflon) tubes (3/1.5 mm inner/ outer diameter).…”
Section: Experimental Design and Field Samplingmentioning
confidence: 99%
See 4 more Smart Citations
“…critical zone, Fe-cycling bacteria, microbial population, redox gradients, riparian sediments and narrow slope, whereas the west bank is adjacent to a flat and wide floodplain. The soil profile consists of post-colonial oxic deposits, pre-colonial anoxic buried wetland soils underlain by suboxic valley-bottom gravel (Lazareva et al, 2022;Sawyer et al, 2014;Walter & Merritts, 2008). Soil pore water was collected by in situ borosilicate glass samplers (50 mm long, 20 mm diameter, 1 μm pore size; Ecotech) with attached PTFE (Teflon) tubes (3/1.5 mm inner/ outer diameter).…”
Section: Experimental Design and Field Samplingmentioning
confidence: 99%
“…Soil pore water was collected by in situ borosilicate glass samplers (50 mm long, 20 mm diameter, 1 μm pore size; Ecotech) with attached PTFE (Teflon) tubes (3/1.5 mm inner/ outer diameter). Six samplers were deployed on both banks (three depths each) with installation of in situ real-time monitoring sensors to measure temperature and redox (details can be found in Lazareva, 2012, Lazareva et al, 2022. No pore water was obtained from the post-colonial deposits owing to unsaturated conditions, and therefore in this study we focused on the water samples extracted from the pre-colonial buried wetland layer (Figure 1).…”
Section: Experimental Design and Field Samplingmentioning
confidence: 99%
See 3 more Smart Citations