“…In particular, the compressive strength diminished from 104 MPa for the GP-free mixture to 74 MPa for the mixture containing 40% GP. As the curing period extended to 28 days, a similar trend endured, although the UHPC mixtures incorporating 5% and 10% GP exhibited strengths above the widely accepted lower threshold of 120 MPa for UHPC [41,52,53]. The mixture devoid of GP demonstrated the highest compressive strength, registering 129 MPa, while the blend containing 40% GP exhibited the lowest, with a reading of 95 MPa.…”
Section: Compressive Strengthmentioning
confidence: 67%
See 1 more Smart Citation
“…In particular, the compressive strength diminished from 104 MPa for the GP-free mixture to 74 MPa for the mixture containing 40% GP. As the curing period extended to 28 days, a similar trend endured, although the UHPC mixtures incorporating 5% and 10% GP exhibited strengths above the widely accepted lower threshold of 120 MPa for UHPC [41,52,53]. The mixture devoid of GP demonstrated the highest compressive strength, registering 129 MPa, while the blend containing 40% GP exhibited the lowest, with a reading of 95 MPa.…”
Section: Compressive Strengthmentioning
confidence: 67%
“…For the formulation of the UHPC blends, two distinct categories of microsteel fibers were utilized. Notably, the authors previously conducted the optimization of these fibers in earlier research [41]. Microscopic analyses of these fibers are visually represented in Figures 7 and 8.…”
Section: Natural Aggregates Steel Fibers and Chemical Admixturesmentioning
confidence: 99%
“…Non-destructive methods, on the other hand, do not involve altering or damaging the structure. Various non-destructive methods are available for monitoring the structural health of concrete, including visual inspection, ultrasonic testing, infrared thermography, and fiber-optic sensing [5][6][7][8][9]. These methods offer information on the condition of structures without causing any alteration, making them a practical and cost-effective choice for monitoring the health of concrete structures over an extended period.…”
Section: Introductionmentioning
confidence: 99%
“…These methods offer information on the condition of structures without causing any alteration, making them a practical and cost-effective choice for monitoring the health of concrete structures over an extended period. They are widely used in real-time monitoring and provide data for condition assessment, trend analysis, and damage identification [7,8].…”
Section: Introductionmentioning
confidence: 99%