37th European Conference and Exposition on Optical Communications 2011
DOI: 10.1364/ecoc.2011.we.10.p1.114
|View full text |Cite
|
Sign up to set email alerts
|

Cost Optimization of Optical In-Building Networks

Abstract: Please check the document version of this publication:• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 8 publications
0
15
0
Order By: Relevance
“…1(b) is set to compensate for the frequency response of the system. This is verified by employing a low-pass filter (600 MHz) at point (1) in Fig. 1(b).…”
Section: Transmission Performance With Spectral Overlappingmentioning
confidence: 66%
See 1 more Smart Citation
“…1(b) is set to compensate for the frequency response of the system. This is verified by employing a low-pass filter (600 MHz) at point (1) in Fig. 1(b).…”
Section: Transmission Performance With Spectral Overlappingmentioning
confidence: 66%
“…Since the main requirements for in-home networks are low cost and ease of installation, large-core polymethyl metacrylate (PMMA)-based plastic optical fiber (POF) is a strong candidate due to its advantages of "doit-yourself" installation [1], simple (or even no) connectorization, easy maintenance and small bending radius. The conventional standard step-index POF (SI-POF) presents a low bandwidth-distance product (< 100 MHz at 50 m) [2].…”
Section: Introductionmentioning
confidence: 99%
“…In the future, POF will most likely displace copper cables for the so-called last mile between the last distribution box of the telecommunication company and the endconsumer (Koonen et al, 2005(Koonen et al, , 2009). Today, copper cables are the most significant bottleneck for high-speed Internet.…”
Section: In-housementioning
confidence: 99%
“…These novel coupler, however, suffer from several disadvantages. The high cost of the available couplers was raised as a challenge to the development of WDM systems in shorthaul networks [5][6][7][8]. In addition, from the stand point of device design, the diameter of the fused tapered region, where stress is concentrated, is too small in conventional couplers.…”
Section: Introductionmentioning
confidence: 99%