2005
DOI: 10.1302/0301-620x.87b10.16468
|View full text |Cite
|
Sign up to set email alerts
|

Cosmetic bilateral leg lengthening

Abstract: The Ilizarov method for leg lengthening was used for cosmetic reasons in 54 patients with constitutional short stature. A mean lengthening of 7 cm with a low rate of complications produced an excellent or good outcome in all the patients, including improvement in psychological disturbances related to short stature. Those who undergo the procedure must be highly motivated, fully informed and understand the technique and possible complications. We suggest that the Ilizarov method for cosmetic limb lengthening is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
45
2

Year Published

2006
2006
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(49 citation statements)
references
References 11 publications
(15 reference statements)
2
45
2
Order By: Relevance
“…Thus we can conclude that a BMD ratio of 0.85 can be taken as a criterion to decide the time of fixator removal with respect to preventing delayed callus subsidence. Study of callus pattern and its correlation with clinical outcome was first performed by Catagni [7], later by Hamanishi et al [13], and recently by Ru Li et al [19]. In our study we used callus patterns seen at the time of fixator removal with only five out of ten patterns noted at the time of fixator removal.…”
Section: Discussionmentioning
confidence: 99%
“…Thus we can conclude that a BMD ratio of 0.85 can be taken as a criterion to decide the time of fixator removal with respect to preventing delayed callus subsidence. Study of callus pattern and its correlation with clinical outcome was first performed by Catagni [7], later by Hamanishi et al [13], and recently by Ru Li et al [19]. In our study we used callus patterns seen at the time of fixator removal with only five out of ten patterns noted at the time of fixator removal.…”
Section: Discussionmentioning
confidence: 99%
“…The same technique is being used to increase the height of somatically normal persons who report negative feelings regarding their short stature [2,6,11,20] deriving from cosmetic, social, and occupational concerns.…”
Section: Introductionmentioning
confidence: 99%
“…Papers describe ''diagnoses'' like ''constitutional short stature,'' use acronyms like ''LFS'' (lengthening for stature) [10,16], and talk about procedures to ''correct'' the condition [11]. Our compliments to those others who call it like it is [5,8].…”
mentioning
confidence: 99%
“…These reports typically have all of the shortcomings associated with this study design: Selection bias, limited followup and, critically, assessment bias. While some of these studies try to rationalize the decisions to do these procedures by describing the psychological dysphoria experienced by patients [1,5,9,13], it is particularly telling that we found none that presented before-and-after results using validated tools (of which many are available) to assess whether the lengthening helped relieve patients of the psychic burden of being ''short.'' Quite simply, it is wrong to measure the results of a procedure designed to address psychological symptoms using only a ruler.…”
mentioning
confidence: 99%
See 1 more Smart Citation