2001
DOI: 10.1016/s0043-1648(01)00753-0
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion response of surface engineered titanium alloys damaged by prior abrasion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
35
0
1

Year Published

2006
2006
2018
2018

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(41 citation statements)
references
References 23 publications
0
35
0
1
Order By: Relevance
“…al. 2014;Hanawa et al 1999;Niinomi, 2003;Pilliar, 2003 Komotori et al 2001;Dearnley, 2005;Güleryüz and Cimenoğlu 2004;Ross and Webster 2013). Titanyum implantlarında yüzeyin pürüzlülüğünü ve osseointegrasyonu artırmak için değişik asit ve alkali kullanılarak yüzey modifikasyonu uzun yıllardır yapılmaktadır.…”
Section: Introductionunclassified
“…al. 2014;Hanawa et al 1999;Niinomi, 2003;Pilliar, 2003 Komotori et al 2001;Dearnley, 2005;Güleryüz and Cimenoğlu 2004;Ross and Webster 2013). Titanyum implantlarında yüzeyin pürüzlülüğünü ve osseointegrasyonu artırmak için değişik asit ve alkali kullanılarak yüzey modifikasyonu uzun yıllardır yapılmaktadır.…”
Section: Introductionunclassified
“…Surface treatments, e.g., thermal oxidation [18][19][20] and anodization, 21) had been performed with results showing improvement of characteristics of oxide layer. Unfortunately, some drawbacks are with these surface treatment methods.…”
Section: Introductionmentioning
confidence: 99%
“…Ti-6Al-4V is a common alloy for ACPs, and is also used in other orthopedic devices such as hip implants, bone plates, and dental implants (Komotori, Lee, Dong, & Dearnley, 2001;Vadiraj & Kamaraj, 2007;Deanrley, Dahm, & Cimenoglu, 2004). Its high strength-to-weight ratio and biocompatibility are effective in the ACP application, where loading and repeated wear are minimal and osseointegration, or the growth of bone cells, is not desirable.…”
Section: Base Metal Corrosion Resistancementioning
confidence: 99%
“…Surface modifications depend on the application, the purpose of the implant, and the state of the Ti-6Al-4V surface upon which they form. Nitrided samples were compared to thermally oxidized Ti-6Al-4V samples by Komotori et al(2001). The open circuit potential (E OC ), or potential of an immersed sample in equilibrium, of thermally oxidized samples was more consistent and reproducible, unlike the scattered E OC values obtained for TiN treatments.…”
Section: Base Metal Corrosion Resistancementioning
confidence: 99%
See 1 more Smart Citation