Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2020
DOI: 10.1039/c9ra09552g
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion protection mechanism of Ce4+/organic inhibitor for AA2024 in 3.5% NaCl

Abstract: Proposed corrosion protection mechanism of Ce4+/ organic inhibitor for AA2024.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
54
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 87 publications
(58 citation statements)
references
References 100 publications
(143 reference statements)
3
54
1
Order By: Relevance
“…In this study, the i corr for bare sample is 13.36 mA cm À2 , while the i corr for CeMCC is 0.24 mA cm À2 , about two orders of magnitude lower than the former. The i corr of CeMCC is lower than that of Mohamed et al, 29 but worse than that of Kanani's research, 33 in which the i corr lowered from 5.1 mA cm À2 to 0.075 mA cm À2 . The strong current reduction observed for the CeMCC can be attributed to the large amount of cerium/molybdenum compounds precipitation on the substrate.…”
Section: Corrosion Resistance Analysiscontrasting
confidence: 64%
See 2 more Smart Citations
“…In this study, the i corr for bare sample is 13.36 mA cm À2 , while the i corr for CeMCC is 0.24 mA cm À2 , about two orders of magnitude lower than the former. The i corr of CeMCC is lower than that of Mohamed et al, 29 but worse than that of Kanani's research, 33 in which the i corr lowered from 5.1 mA cm À2 to 0.075 mA cm À2 . The strong current reduction observed for the CeMCC can be attributed to the large amount of cerium/molybdenum compounds precipitation on the substrate.…”
Section: Corrosion Resistance Analysiscontrasting
confidence: 64%
“…The physical explanation of low-frequency inductive loop is not sufficiently clear; it has been attributed to the relaxation of adsorbed intermediate species 57 and/or formation of a passive layer and/or redox activity. 29 In this work, the inductive loop of the two coated samples may be related to redox activity, which may indicate that Ce(IV) undergoes a redox process in the low frequency region. The Bode plots are presented in Fig.…”
Section: Corrosion Resistance Analysismentioning
confidence: 80%
See 1 more Smart Citation
“…The former of these experiments reproduced the aqueous corrosive ions from the surface of the Epoxy/1.8 ZnO-NiO coating, while the latter generated an impediment in the dissemination of the ionic electrolyte, which created the notable corrosion defensive capability in the nanostructured metal oxide composite coatings [59][60][61][62][63][64][65][66][67][68]. Figure 6.…”
Section: Corrosion Inhibition Mechanismmentioning
confidence: 95%
“…Table4and fig9 shows the weight loss of mild steel coated with Aluminum paint (without inhibitor) in different corrosive medium. It is clear from the table that after seven weeks the weight of the mild steel coated with Aluminum paint (without inhibitor) decreased to 82.92 g, 82.90 g, 82.89 g, and 82.87 g, respectively in the tap water, in seawater the weight of coated mild steel decreased to 82.43 g, 82.39 g, 82.37 g and 82.33 g respectively whereas in 3% of Na2CO3 solution the weight of coated mild steel decreased to 81.99 g, 81.98 g, 81.98 g and 81.97g respectively.…”
mentioning
confidence: 99%