Metallic Biomaterials Processing and Medical Device Manufacturing 2020
DOI: 10.1016/b978-0-08-102965-7.00014-x
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion of metallic biomaterials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 178 publications
0
5
0
Order By: Relevance
“…This difference is reasonable and well documented. 8,11 For zinc, a recent review 8 observed a difference of about 2 to 6 times between the estimated corrosion rate values derived from polarization and immersion tests. These two corrosion tests are inherently disparate, and direct comparisons of derived CR values would be inadvisable.…”
Section: Weight Loss Measurementmentioning
confidence: 99%
See 2 more Smart Citations
“…This difference is reasonable and well documented. 8,11 For zinc, a recent review 8 observed a difference of about 2 to 6 times between the estimated corrosion rate values derived from polarization and immersion tests. These two corrosion tests are inherently disparate, and direct comparisons of derived CR values would be inadvisable.…”
Section: Weight Loss Measurementmentioning
confidence: 99%
“…This is also consistent with the literature that does not report the presence of ZnSO 4 -based corrosion products when Zn is exposed to physiological fluids. 8,11 This would indicate that though sulfates could create protective Zn compound films, such compounds were not present in the layer. This is reasonable since the sulfate cation would compete with the other cations, and its relatively small amount in S4 would put it at a thermodynamic disadvantage.…”
Section: Zn Corrosion Mechanism In the Differentmentioning
confidence: 99%
See 1 more Smart Citation
“…Magnesium has the fastest corrosion rate, followed by zinc, and iron. 135 Each element is an essential nutrient. The recommended daily intake is 320–420 mg of magnesium, 6.5–15 mg of zinc, and 10–20 mg of iron.…”
Section: Biodegradable Metals As Candidates For Pelvic Meshmentioning
confidence: 99%
“…The recommended daily intake is 320–420 mg of magnesium, 6.5–15 mg of zinc, and 10–20 mg of iron. 135,136 However, uncontrolled and non-uniform corrosion is a possible concern. 51,137,138 This requires that the biodegradable metal for any application must be chosen to have the appropriate uniform corrosion rate that is appropriate to the particular application so that the biodegradable metal component (mesh, screw, wire etc .)…”
Section: Biodegradable Metals As Candidates For Pelvic Meshmentioning
confidence: 99%