2019
DOI: 10.1016/j.arabjc.2014.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion inhibition of carbon steel immersed in a 1 M HCl solution using benzothiazole derivatives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
38
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 119 publications
(49 citation statements)
references
References 23 publications
2
38
0
Order By: Relevance
“…The corresponding electrical equivalent circuits, along with the related fitted parameters for the initial and long-term immersion, are shown in Figure 13a,b, respectively. The fitted parameters include the following factors: R1-solution resistance, R2 and Q1 (capacitor), related to the double layer [19,20], R3 and Q2, corresponding to charge transfer resistance and capacitor, respectively, which are related to the effect of corrosion products and the time constant that appeared in the low frequency region [21,22]. Stress corrosion examination of the printed ER70S-6 and reference ST-37 alloys by slow strain rate testing (SSRT) in 3.5% NaCl solution in terms of UTS and elongation are shown in Figures 14 and 15, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The corresponding electrical equivalent circuits, along with the related fitted parameters for the initial and long-term immersion, are shown in Figure 13a,b, respectively. The fitted parameters include the following factors: R1-solution resistance, R2 and Q1 (capacitor), related to the double layer [19,20], R3 and Q2, corresponding to charge transfer resistance and capacitor, respectively, which are related to the effect of corrosion products and the time constant that appeared in the low frequency region [21,22]. Stress corrosion examination of the printed ER70S-6 and reference ST-37 alloys by slow strain rate testing (SSRT) in 3.5% NaCl solution in terms of UTS and elongation are shown in Figures 14 and 15, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…onto the metal surface, making it more resistant to corrosion than the panel subjected to the solution without inhibitor additives. Moreover, it may be remarked that MBT acts as a mixed inhibitor for mild steel in NaCl solutions [78]. The polarization curves recorded for mild steel panels in the presence or absence of inhibitors after subjection in WSS for 24 h are demonstrated in Figure 17.…”
Section: Appl Sci 2019 9 X For Peer Review 18 Of 38mentioning
confidence: 92%
“…The increase in potential is assigned to the creation of protective films onto the metal surface, making it more resistant to corrosion than the panel subjected to the solution without inhibitor additives. Moreover, it may be remarked that MBT acts as a mixed inhibitor for mild steel in NaCl solutions [78].…”
Section: Electrochemical Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Depending on the category of the inhibitor they act by film formation, selective precipitation and/ or alteration of the corrosive environment [13]. Research on green corrosion inhibitors shows it acts through film formation on carbon steels with good inhibition protection [14][15][16][17]. In contribution to research on corrosion prevention through appropriate material selection and chemical control, this research aims to study the synergistic combination effect of 4-methyl-norvalin and 2-methoxy-4-formylphenol organic derivatives on the corrosion of P4 low carbon mold steel in dilute H 2 SO 4 and HCl solution.…”
Section: Introductionmentioning
confidence: 99%