Abstract:The electrochemical reaction response of austenitic 316L stainless steel and carbon steel was examined through weight loss analysis in 1M, 2M and 3M of HCl acid. The results show that austenitic 316L has high corrosion resistance than carbon steel for the test analyzed with the lowest corrosion rate of 0.0018mm/y at 1M of HCl and highest at 0.0053mm/y when compared with carbon steel which has the lowest corrosion rate of 0.0003mm/y for 1M of HCl and highest at 0.0013 mm/y of 3M of HCl solution all at ambient t… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.