2015
DOI: 10.1016/j.corsci.2015.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion behavior of a self-sealing pore micro-arc oxidation film on AM60 magnesium alloy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
33
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 80 publications
(36 citation statements)
references
References 35 publications
1
33
0
Order By: Relevance
“…added graphene oxide into the electrolyte and found that the number of pores on the PEO coating was significantly decreased 22 . Moreover, some researchers tried to fabricate self-sealing PEO coating on Mg alloys 9 , 10 , 13 . Dong et al .…”
Section: Introductionmentioning
confidence: 99%
“…added graphene oxide into the electrolyte and found that the number of pores on the PEO coating was significantly decreased 22 . Moreover, some researchers tried to fabricate self-sealing PEO coating on Mg alloys 9 , 10 , 13 . Dong et al .…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, only one EEC can be observed. components of impedance increased gradually after 1 h of exposure ( Figure 4a) attributed to the treatment [53]. The AC sample exhibits a smaller magnitude semi-circle compared to treated coating owing to the presence of defects on the surface (Figures 1a and 2a) which allows the ingress of the NaCl solution through the defects and causes a localized attack.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%
“…Figure 4 shows the complex-plane impedance plots of the coatings at different exposure periods in 3.5 wt.% NaCl solution. As the concentration of NaH 2 PO 4 increased with 0.1 M Ca(NO 3 ) 2 , the magnitude of the real and imaginary components of impedance increased gradually after 1 h of exposure ( Figure 4a) attributed to the treatment [53]. The AC sample exhibits a smaller magnitude semi-circle compared to treated coating owing to the presence of defects on the surface (Figures 1a and 2a) which allows the ingress of the NaCl solution through the defects and causes a localized attack.…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%
“…The anti-corrosion properties of K2ZrF6 were attributed to the activating surface of the substrate by the K2ZrF6 additives. Serval other authors have previously carried out experiments using K2ZrF6 in order to understand the properties and significance of the K2ZrF6 additives in primary step coatings [17][18][19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%