1996
DOI: 10.5006/1.3292080
|View full text |Cite
|
Sign up to set email alerts
|

Corrosion Assessment of Regenerative Preheaters in Oil-Fired Power Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…8 presents the potential and current noise time series and noise resistance at 60 o C, under dynamic conditions. The noise time series present high amplitude low frequency with superimposed low amplitude high frequency oscillations, associated to generalized corrosion under diffusion control [13]. The noise resistance oscillated between 500 Kohms-cm 2 and 3 Mohms-cm 2 .…”
Section: Impedancementioning
confidence: 98%
“…8 presents the potential and current noise time series and noise resistance at 60 o C, under dynamic conditions. The noise time series present high amplitude low frequency with superimposed low amplitude high frequency oscillations, associated to generalized corrosion under diffusion control [13]. The noise resistance oscillated between 500 Kohms-cm 2 and 3 Mohms-cm 2 .…”
Section: Impedancementioning
confidence: 98%
“…20,21) The mechanism and aggressiveness of SO 2 corrosion has been reported in many literatures. 7,22,23) Combustion, however, typically involves the emission of smoke particles and hydrocarbons along with SO 2 .…”
Section: Introductionmentioning
confidence: 99%