Correlations between different tonometries and ocular biometric parameters in patients with primary congenital glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 19 publications
(10 reference statements)
1
6
0
Order By: Relevance
“…There are several studies regarding corneal thickness in children but comparative studies are very rare. In the reports, the range of corneal thickness changes from 529 to 564 µm and the average is likely 550 µm (Faramarzi et al 2010;Bradfield et al 2011;Fern et al 2012;Resende et al 2012;Sahin et al 2008;Coste et al 2008;Hussein et al 2004;Mendes et al 2011). In our study, central corneal thickness is 548 µm in the study group and 559 µm in the control group.…”
Section: Central Corneal Thicknesssupporting
confidence: 48%
“…There are several studies regarding corneal thickness in children but comparative studies are very rare. In the reports, the range of corneal thickness changes from 529 to 564 µm and the average is likely 550 µm (Faramarzi et al 2010;Bradfield et al 2011;Fern et al 2012;Resende et al 2012;Sahin et al 2008;Coste et al 2008;Hussein et al 2004;Mendes et al 2011). In our study, central corneal thickness is 548 µm in the study group and 559 µm in the control group.…”
Section: Central Corneal Thicknesssupporting
confidence: 48%
“…DCT measurements were required to have a quality value of Q1 or Q2. Goldmann Applanation Tonometry was performed using the AT 900 (Haag-Streit, Koeniz, Switzerland) [7,8,[11][12][13][14]. Before each measurement, topical anesthetic eye drops 0.5% topical The system presents images with sectional planes of 90 and 180 degrees, and the distribution of total measurement points distributed in several measurements from the apex of the cornea to its periphery, in grayscale.…”
Section: Intraocular Pressure Measurementsmentioning
confidence: 99%
“…DCT measurements were required to have a quality value of Q1 or Q2. Goldmann Applanation Tonometry was performed using the AT 900 (Haag-Streit, Koeniz, Switzerland) [7,8,[11][12][13][14]. Before each measurement, topical anesthetic eye drops 0.5% topical proparacaine hydrochloride (Anestalcon, Alcon Laboratories, Inc., Fort Worth, TX, USA) and fluorescein eye drops (Fluoresceina Sódica, Ophthalmos, SP, Brazil) were instilled in each eye.…”
Section: Intraocular Pressure Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“… 6 In this regard, central corneal thickness (CCT) has also been demonstrated to be associated with the onset and progression of glaucoma. 7 Moreover, thicker or thinner central corneas may lead to either overestimation or underestimation of intraocular pressure (IOP), 8 , 9 which is the most important causal and treatable risk factor for glaucoma. Previous studies indicated that CCT profile affects Goldmann applanation tonometry–measured IOP.…”
Section: Introductionmentioning
confidence: 99%