2002
DOI: 10.1016/s0041-1345(02)03603-5
|View full text |Cite
|
Sign up to set email alerts
|

Correlation of blood-free graft weight and volumetric graft volume by an analysis of blood content in living donor liver grafts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
45
0
2

Year Published

2006
2006
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(53 citation statements)
references
References 3 publications
2
45
0
2
Order By: Relevance
“…They found that intraoperative blood loss is the main reason for overestimation. Hwang et al found a difference between CT measurement and blood-free water displacement volumetry of 20 % but only a difference of 4 % between blood-filled graft volume and CT volumetry [19]. In view of these results, overestimation of liver volume in the present study can be fully explained.…”
Section: Resected Liver Volumesupporting
confidence: 44%
“…They found that intraoperative blood loss is the main reason for overestimation. Hwang et al found a difference between CT measurement and blood-free water displacement volumetry of 20 % but only a difference of 4 % between blood-filled graft volume and CT volumetry [19]. In view of these results, overestimation of liver volume in the present study can be fully explained.…”
Section: Resected Liver Volumesupporting
confidence: 44%
“…calculation, inter-observer variations, deviation from the virtual preoperative cutting plane, variability of steatosis and level of hydration at the time of the scanning, gender related variation of liver density and finally difference when scanning a liver perfused with blood and when flushed with preservation solutions [17,18].…”
Section: Resultsmentioning
confidence: 99%
“…Altogether with difference in density and debatable one to one basis, other factors could contribute to the discrepancy between CT estimated graft volume and AGW including CT pitfalls, variations in CT machine and softwares of volume between CT volumetric measurement and AGW as close as feasible [17,20,21].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…One explanation for this may be the decreased blood content after graft resection compared to the physiologically perfused graft at the time of CT examination [46]. Hwang et al observed an average blood proportion in 12 right lobe grafts of about 30 ml/100 g [47]. However, a mismatch between the simulated and the actual resection line at the hepatectomy cannot be excluded and is difficult to measure.…”
Section: Discussionmentioning
confidence: 99%