2021
DOI: 10.1186/s13014-021-01861-y
|View full text |Cite
|
Sign up to set email alerts
|

Correlation between the γ passing rates of IMRT plans and the volumes of air cavities and bony structures in head and neck cancer

Abstract: Background Both patient-specific dose recalculation and γ passing rate analysis are important for the quality assurance (QA) of intensity modulated radiotherapy (IMRT) plans. The aim of this study was to analyse the correlation between the γ passing rates and the volumes of air cavities (Vair) and bony structures (Vbone) in target volume of head and neck cancer. Methods Twenty nasopharyngeal carcinoma and twenty nasal natural killer T-cell lymphoma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 40 publications
(56 reference statements)
0
3
0
1
Order By: Relevance
“…It means that the dose difference between the D 95% prescription and others becomes more pronounced. Although the dose differences between AAA and AXB for IMRT and VMAT decrease because of dose compensation from out of field [ 9 , 17 ], the dose differences between calculation algorithms are large when the target’s air content is large.…”
Section: Discussionmentioning
confidence: 99%
“…It means that the dose difference between the D 95% prescription and others becomes more pronounced. Although the dose differences between AAA and AXB for IMRT and VMAT decrease because of dose compensation from out of field [ 9 , 17 ], the dose differences between calculation algorithms are large when the target’s air content is large.…”
Section: Discussionmentioning
confidence: 99%
“…Consideran además como buena práctica establecer diferentes tolerancias en función de la complejidad de la técnica, algo que se refleja también con frecuencia en la bibliografía. [268][269][270][271] Una consecuencia de dicha retroalimentación podría ser modificar o adquirir nuevo equipamiento o mejorar el entrenamiento del personal.…”
Section: Limitaciones Sensibilidad Y Especificidad De Los Sistemas De...unclassified
“…[61] Standard collection tools of gamma passing rates are 2D or 3D matrix devices and tools that come with the accelerator manufacturer, such as Varian portal dosimetry (PD). The patient anatomical site variations and structural differences, [62] TPS algorithms, [63] plan complexity, [47] and device accuracy [64] will likely affect gamma passing rates. Halcyon's gantry rotation speed and MLC motion speed are faster than C-arm accelerators, so the dose delivery accuracy of SRT plans is a problem worth studying.…”
Section: Gamma Passing Ratesmentioning
confidence: 99%