2015
DOI: 10.1039/c5ta05545h
|View full text |Cite
|
Sign up to set email alerts
|

Correlation between scratch healing and rheological behavior for terpyridine complex based metallopolymers

Abstract: The healing phenomenon of metallopolymers is studied in detail and the dependency of the chosen metal salt is provided. Furthermore, a correlation between the supramolecular bond life time and the healing behavior could be revealed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
70
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 81 publications
(73 citation statements)
references
References 86 publications
(94 reference statements)
3
70
0
Order By: Relevance
“…This material was obtained after the bulk polymerization of BMA and 1,6-hexanediol dimethacrylate according to procedures reported in the literature. 23 The degree of crosslinking was 5% and, thus, was comparable with P1.…”
Section: Resultsmentioning
confidence: 73%
See 3 more Smart Citations
“…This material was obtained after the bulk polymerization of BMA and 1,6-hexanediol dimethacrylate according to procedures reported in the literature. 23 The degree of crosslinking was 5% and, thus, was comparable with P1.…”
Section: Resultsmentioning
confidence: 73%
“…Furthermore, P4, the reference polymer without any reversible moiety, featured no scratch-healing ability, as reported in the literature. 23 In addition to the scratch-healing tests, tensile testing was performed. For this purpose, the above-described bulk polymerization was performed in a Teflon mold to obtain dog bone-shaped specimens (Supplementary Information; Supplementary Figure S22).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…As a result, the frequency dependence of storage shear modulus, G′, of the water saturated specimen intersects with that of loss shear modulus, G″, suggesting a transition from elastic-like (G′ > G″) to viscous-like (G′ < G″) with decreasing frequency (Figure 4a). Since the disconnected networks need time to be reconnected, the system has to perform like viscous fluid at low frequency regime [12][13][14]. In contrast, the dry HBPU-DMPA-[Fe(DOPA) 3 ] (Figure 4b) and the control without Fe 3+ (Figure 4c) do not exhibit the same network reconfiguration due to lack of the dynamic bonds.…”
Section: Resultsmentioning
confidence: 99%