2006
DOI: 10.1097/00061198-200604000-00003
|View full text |Cite
|
Sign up to set email alerts
|

Correlation Between Intraocular Pressure, Central Corneal Thickness, Stage of Glaucoma, and Demographic Patient Data

Abstract: Glaucoma patients with thin central corneal thickness are more likely to be found at an advanced stage of the disease and among those with normal-tension glaucoma and black African ancestry. Underestimation of intraocular pressure by Goldmann applanation tonometry could be one causative factor.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

13
82
4
18

Year Published

2007
2007
2022
2022

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 115 publications
(117 citation statements)
references
References 29 publications
13
82
4
18
Order By: Relevance
“…Similar results, in spite of different mean values, have been reported by previous investigations. 16,[19][20][21][23][24][25][26][27][28][29][30][31]35,36 The DIOP between DCT and GAT readings was higher in healthy than in glaucomatous eyes, either with open-angle or angleclosure phenotypes (Table 1). The same outcome has been found by analysing IOP measurements obtained by DCT and GAT in different groups of subjects with the same CCT value, except for POAG subjects with thinner corneas.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Similar results, in spite of different mean values, have been reported by previous investigations. 16,[19][20][21][23][24][25][26][27][28][29][30][31]35,36 The DIOP between DCT and GAT readings was higher in healthy than in glaucomatous eyes, either with open-angle or angleclosure phenotypes (Table 1). The same outcome has been found by analysing IOP measurements obtained by DCT and GAT in different groups of subjects with the same CCT value, except for POAG subjects with thinner corneas.…”
Section: Discussionmentioning
confidence: 99%
“…16 DCT was designed to be largely independent of structural properties of the cornea and to eliminate most of the systematic errors arising from physiological variables of the eye, which render GAT less accurate. 17 Some recent studies compared the performance of the new device against other tonometers [18][19][20][21][22] considering either the influence of pachymetry on IOP readings [23][24][25][26] or the impact of refractive surgery as a source of errors in applanation tonometry. [27][28][29][30] Only two studies evaluated ocular structural factors other than pachymetry influencing IOP measurements in healthy subjects 31 or African American subjects.…”
Section: Introductionmentioning
confidence: 99%
“…A medida da ECC tornou-se um importante fator biométrico e é parte essencial na propedêutica do glaucoma (3)(4)(5)(11)(12) . Os valores da PIO obtidos com o TCDP em nosso estudo foram maiores que os encontrados com o TAG (3,4,11) .…”
Section: Discussionunclassified
“…A pressão intra-ocular (PIO) é um fator de risco importante no diagnóstico, progressão e tratamento do glaucoma, embora os valores obtidos apresentem uma baixa sensibilidade e uma baixa especificidade (1)(2)(3)(4) . A determinação precisa da PIO é um importante passo na detecção e seguimento do glaucoma, primário ou secundário, bem como no diagnóstico diferencial de glaucoma primário de ângulo aberto, glaucoma de pressão normal e hipertensão ocular (3,5) .…”
Section: Introductionunclassified
See 1 more Smart Citation