2018
DOI: 10.1016/j.ejmp.2018.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Correlation between gamma passing rate and complexity of IMRT plan due to MLC position errors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 25 publications
0
14
0
Order By: Relevance
“…were closely linked with the features of the specific structure, the treatment site, the QA equipment, the delivery technique and so on [31][32][33][34] . Therefore, it is necessary for the medical physicist to carry out an objective analysis based on the actual situation, and to cor- In our study, by setting 5% DVH action levels and 90% GPs action levels for DVH_GPs analysis, we were able to further reveal the TP, FR, TN, and FN indicators in the evaluation results.…”
Section: B | Qa Results After Shifting Of Delta4 Phantommentioning
confidence: 99%
“…were closely linked with the features of the specific structure, the treatment site, the QA equipment, the delivery technique and so on [31][32][33][34] . Therefore, it is necessary for the medical physicist to carry out an objective analysis based on the actual situation, and to cor- In our study, by setting 5% DVH action levels and 90% GPs action levels for DVH_GPs analysis, we were able to further reveal the TP, FR, TN, and FN indicators in the evaluation results.…”
Section: B | Qa Results After Shifting Of Delta4 Phantommentioning
confidence: 99%
“…Wang et al. ( 24 ) have also reported that MLC positional errors have a distinguishable dosimetric effect relative to other linac errors. It was not hard to understand why our study focused on the effect of the systematic MLC positional errors in DVH metrics.…”
Section: Discussionmentioning
confidence: 99%
“…MLC errors mainly include individual MLC positional errors, random MLC positional errors and systematic positional errors. Individual MLC positional errors or random MLC positional errors have little dosimetric effect on RapidArc plans ( 24 ). As such, systematic MLC positional errors were introduced in this study.…”
Section: Methodsmentioning
confidence: 99%
“…MLC errors mainly include random MLC positional errors and systematic positional errors. Random MLC positional errors have little dosimetric effect on IMRT plans ( 28 ). Steers and Fraass ( 23 ) concluded that the shifts in different directions may be an indication of different types of systematic errors arising from TPS model issues, machine issues, or other device issues.…”
Section: Discussionmentioning
confidence: 99%