1977
DOI: 10.1021/ac50009a057
|View full text |Cite
|
Sign up to set email alerts
|

Correction. Tube Cracker for Opening Glass-Sealed Ampoules under Vacuum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

1986
1986
2011
2011

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…From this we deduced, that a fractionating adsorption process occurs on the fresh glass surface. Although the tube cracker technique is well established for many decades (Des Marais and Hayes, 1976;Caldwell et al, 1983), this method is generally applied for dual inlet-Multiport measurements with CO 2 amounts a factor of 100 larger than in our case.…”
Section: Humidifiermentioning
confidence: 94%
“…From this we deduced, that a fractionating adsorption process occurs on the fresh glass surface. Although the tube cracker technique is well established for many decades (Des Marais and Hayes, 1976;Caldwell et al, 1983), this method is generally applied for dual inlet-Multiport measurements with CO 2 amounts a factor of 100 larger than in our case.…”
Section: Humidifiermentioning
confidence: 94%
“…The cellulose sample (20 mg), copper oxide, and a piece of silver foil were loaded into quartz tubes, the tubes evacuated to less than 10 Ϫ2 Torr, sealed off with an oxy-butane torch, and heated for a minimum of 4 h at 800°C (Sofer, 1980;Sealy, 1986). After cooling, the tubes were removed from the furnace, scored in the middle to ensure easy cracking and to prevent splitting, and inserted into a cracker of the type described by Desmarais and Hayes (1976). The combustion process produces CO 2 , nitrogen, and water vapor which are separated from each other on a cryogenic gas separation line into which the tube was inserted (Sealy, 1986).…”
Section: Methodsmentioning
confidence: 99%
“…Milk, feed and tissue samples were combusted to CO2 in evacuated, sealed quartz tubes (Boutton et al, 1983). After combustion, sample tubes were opened under vacuum (Des Marais and Hayes, 1976), the CO2 was isolated and purified by cryogenic distillation and the volume of CO2 produced was measured manometrically for calculation of percentage carbon. The CO2 then was transferred into 20-cc vacutainers and analyzed for 13C/12C on an automated isotope ratio mass spectrometer 7 (Schoeller and Klein, 1979).…”
Section: Sample Preparation and Mass Spectrometrymentioning
confidence: 99%