Abstract: Susceptibility artifacts caused by stainless steel orthodontic appliances (braces) pose significant challenges in clinical brain MRI examinations. We introduced field correction device (FCD) utilizing permanent magnets to cancel the induced B0 inhomogeneity and mitigate geometric distortions in MRI. We evaluated a prototype FCD using a 3D-printed head phantom in this proof of concept study. The phantom was compartmented into anterior frontal lobe, temporal lobe, fronto-parieto-occipital lobe, basal ganglia and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 12 publications
(12 reference statements)
0
2
0
Order By: Relevance
“…For example, yellow bone marrow exhibits a low DWI SI and very low ADC values because of its abundance of fat cells (and thus hydrophobicity) while red marrow shows a higher DWI SI and ADC values due to its higher water content and cellularity ( Figure 4 ). 6 A range of ADC values by structure and tissue type is displayed in Table 2 . In addition to the DWI offering insight into the water content and cellular density of body tissues, DWI also offers improved visualization of small structures due to excellent background suppression, e.g .…”
Section: Normal Msk Tissue Appearances On Diffusion Imagingmentioning
confidence: 99%
“…For example, yellow bone marrow exhibits a low DWI SI and very low ADC values because of its abundance of fat cells (and thus hydrophobicity) while red marrow shows a higher DWI SI and ADC values due to its higher water content and cellularity ( Figure 4 ). 6 A range of ADC values by structure and tissue type is displayed in Table 2 . In addition to the DWI offering insight into the water content and cellular density of body tissues, DWI also offers improved visualization of small structures due to excellent background suppression, e.g .…”
Section: Normal Msk Tissue Appearances On Diffusion Imagingmentioning
confidence: 99%
“…Some authors have mentioned the use of a mouthpiece as a spacer for avoiding backscatter and other prototypes of field correcting devices. [ 24 25 ] The MRI safe splint is an innovative technique and is helpful to assure safety during the MRI, it can be advised and fabricated during the pre MRI dental examination.…”
Section: Introductionmentioning
confidence: 99%