2013
DOI: 10.1016/j.jcrs.2013.06.027
|View full text |Cite
|
Sign up to set email alerts
|

Correcting astigmatism with toric intraocular lenses: Effect of posterior corneal astigmatism

Abstract: Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido-dual Scheimpflug analyzer. A new toric IOL nomogram is proposed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
190
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
5

Relationship

1
9

Authors

Journals

citations
Cited by 250 publications
(201 citation statements)
references
References 13 publications
9
190
2
Order By: Relevance
“…One remarkable disadvantage of the VERION System is that posterior corneal surface measurement is not possible; this may have a significant role in a relatively high percentage of the patients, especially those waiting for toric IOL implantation. 11 Another disadvantage of the system is that another tool measuring the axial length is required for the completion of the calculations for cataract surgery (ie, IOL diopter planning).…”
Section: Discussionmentioning
confidence: 99%
“…One remarkable disadvantage of the VERION System is that posterior corneal surface measurement is not possible; this may have a significant role in a relatively high percentage of the patients, especially those waiting for toric IOL implantation. 11 Another disadvantage of the system is that another tool measuring the axial length is required for the completion of the calculations for cataract surgery (ie, IOL diopter planning).…”
Section: Discussionmentioning
confidence: 99%
“…A second study by Koch et al (35) reported in pseudophakic eyes the mean corneal astigmatism prediction error of four devices that calculate total corneal astigmatism based only on anterior surface measurements. The corneal astigmatism prediction error (the deviation from the actual total corneal astigmatism) was obtained by subtracting the actual corneal astigmatism (which is the difference between the postoperative manifest refraction corrected to the corneal plane and the effective toric IOL power calculated with the Holladay IOL Consultant Program (Holladay Consulting, Inc., Bell Air, USA) from the corneal astigmatism measured by each device.…”
Section: The Role Of the Posterior Corneamentioning
confidence: 99%
“…With new multifocal IOLs on board and refractive or presbyopic lens exchange becoming more popular, there is no room for inaccurate measurements. Addressing posterior corneal astigmatism has become an important issue when dealing with toric monofocal or toric multifocal IOLs [1][2][3][4]. The posterior corneal curvature can be assessed with optical coherence tomography (OCT) systems (Casia SS-1000, Tomey Corp.) and Scheimpflug camera-based devices such as Pentacam HR Ò (Oculus Optikgerate GmbH), Galilei Ò (Ziemer Ophthalmic Systems AG) and Sirius Ò (Schwind).…”
Section: Introductionmentioning
confidence: 99%