1991
DOI: 10.1161/01.cir.83.5.1788
|View full text |Cite
|
Sign up to set email alerts
|

Coronary stenting with a new, radiopaque, balloon-expandable endoprosthesis in pigs.

Abstract: Background. Intracoronary stents may be effective when used as "bail-out" devices for acute complications after percutaneous transluminal coronary angioplasty. Furthermore, preliminary reports have demonstrated some promising results with stents with regard to the reduction of restenosis. Several stent devices are available for preclinical and clinical evaluation. The use of these stainless-steel stents has been limited by poor visibility during fluoroscopy and thrombogenicity during the first days to weeks af… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
20
0
1

Year Published

1991
1991
2002
2002

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 73 publications
(23 citation statements)
references
References 36 publications
2
20
0
1
Order By: Relevance
“…The metal composition and characteristics of the stent surface may also be important for the performance of the implanted stent. [93][94][95][96][97][98][99][100][101][102] Another factor that must be considered when assessing stent design is the mode of delivery: self-expanding versus balloon-expandable. The currently available self-expanding stents are configured as a slotted tube (Radius) or as a wire mesh (Wallstent) and are composed of either nitinol (Radius) or stainless steel (Wallstent).…”
Section: Are They All Equivalent?mentioning
confidence: 99%
“…The metal composition and characteristics of the stent surface may also be important for the performance of the implanted stent. [93][94][95][96][97][98][99][100][101][102] Another factor that must be considered when assessing stent design is the mode of delivery: self-expanding versus balloon-expandable. The currently available self-expanding stents are configured as a slotted tube (Radius) or as a wire mesh (Wallstent) and are composed of either nitinol (Radius) or stainless steel (Wallstent).…”
Section: Are They All Equivalent?mentioning
confidence: 99%
“…The protocol was approved by the Committee on experimental animals of the Erasmus University. After anaesthesia and under sterile conditions an arteriotomy of the left carotid artery was performed and a 9F introduction sheath was placed as described earlier [6,10]. After administration of 5000 IU of heparin sodium, an 8F catheter was advanced to the infrarenal abdominal aorta.…”
Section: In Vivo Stent Implantationmentioning
confidence: 99%
“…Results from uncontrolled clinical studies with stainless steel stents in the coronary circulation indicate, however, that these devices are prone to (sub)-acute thrombotic occlusion and do not eliminate the incidence of restenosis, although they reduce its occurrence [2][3][4][5]. In animal experiments coronary stents composed of tantalum proved to be less thrombogenic than stainless steel stents [6]~but the initial results after implantation in patients showed no detectable advantage of tantalum [7]. Applying a polymer coating to metal stents proved effective in reducing the thrombogenicity of these devices in experimental animals [8].…”
Section: Introductionmentioning
confidence: 99%
“…The prosthesis is crimped onto a deflated polyethylene angioplasty balloon and the maximal diameter of the balloon after inflation determines the ultimate size of the prosthesis after implantation [ 5 ] .…”
Section: Stent Typesmentioning
confidence: 99%