Coronary Sinus Lead Extraction in the Era of Cardiac Resynchronization Therapy:

Abstract: As the number of coronary sinus (CS) lead implantations for cardiac resynchronization therapy increases so will the need for extraction of these leads. The safety of extraction of leads from the branches of the CS has not been reported. We reviewed our database of patients undergoing pacemaker lead extraction from January 2002 through February 2004 at our institution. Of 149 patients referred for lead extraction, 14 (9%) had a biventricular device. The indications for lead extraction were infection, lead malfu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
22
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(24 citation statements)
references
References 8 publications
2
22
0
Order By: Relevance
“…Previous series of CS lead removal are also heterogeneous in the explantation technique used after manual traction. For example, Tyres et al 3 used powered sheaths, Kasravi et al 4 used femoral snares, Bongiorni et al 7 used mechanical dilatation, and Burke et al 6 used the laser sheath. Regardless, all of these studies, and the present study, achieved a high procedural success rate (98–100%) for CS lead extraction, indicating that CS lead extraction is technically feasible.…”
Section: Discussionmentioning
confidence: 99%
“…Previous series of CS lead removal are also heterogeneous in the explantation technique used after manual traction. For example, Tyres et al 3 used powered sheaths, Kasravi et al 4 used femoral snares, Bongiorni et al 7 used mechanical dilatation, and Burke et al 6 used the laser sheath. Regardless, all of these studies, and the present study, achieved a high procedural success rate (98–100%) for CS lead extraction, indicating that CS lead extraction is technically feasible.…”
Section: Discussionmentioning
confidence: 99%
“…The latter will also lead to an increasing requirement for coronary sinus lead extraction. Experience in removal of these leads is being published 16–19 . The CS leads that were part of CRT devices were all removed with gentle traction.…”
Section: Discussionmentioning
confidence: 99%
“…The extraction in the one patient, however, was smooth and without any complications. Similarly, Kasravi et al 4 report on CS lead extraction in 14 patients. A total of 13 leads were extracted from the CS and its tributaries smoothly without difficulty.…”
Section: Discussionmentioning
confidence: 91%
“…Electrodes with fixation tines at the end (Easytrak, Easytrak 2, Guidant) do not seem to represent any serious problem during the removal either. In fact, 2 out of 14 extracted leads in aforementioned patients cohort 4 were tined leads. Another serious problem might be the inability to insert a locking stylet into the lead during extraction due to intraluminal thrombotic occlusion, 4 which may be desirable for tensile strength and support during gradual traction.…”
Section: Discussionmentioning