2020
DOI: 10.1016/j.gloei.2020.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Coordinated control strategy for a PV-storage grid-connected system based on a virtual synchronous generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 5 publications
0
15
0
1
Order By: Relevance
“…In the case of PV generation, literature [60,61] presented a PV-VSG technology, which considers the dynamic features of PV power, allowing for many PV units to connect to the grid via VSG. It enables the connect-off-grid operation that is both flexible and reliable, and it is critical to enabling grid-friendly access distributed PV power generation.…”
Section: Application Of Vsgmentioning
confidence: 99%
“…In the case of PV generation, literature [60,61] presented a PV-VSG technology, which considers the dynamic features of PV power, allowing for many PV units to connect to the grid via VSG. It enables the connect-off-grid operation that is both flexible and reliable, and it is critical to enabling grid-friendly access distributed PV power generation.…”
Section: Application Of Vsgmentioning
confidence: 99%
“…China has also taken the use of renewable energy to cope with energy depletion and environmental problems as an important development strategy and put forward the "3060" dual carbon goal [1]. The large-scale access of new energy generation such as wind power and photovoltaic makes the grid gradually present characteristics of low inertia [2], which brings many challenges to the safe and stable operation of the power system [3]. For example, a series of sub-synchronous oscillation accidents occurred in Guyuan wind farm in Hebei from 2012 to 2015, the sub/super-synchronous oscillation accident caused by a wind farm occurred in Hami, Xinjiang in 2015 under a weak grid, and the sub-synchronous oscillation accident occurred in ERCOT in the United States in 2017.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, the grid-connected inverter interface power supply is mainly divided into two basic control methods: currentsource inverter based on PLL and voltage-source inverter based on droop control [3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the literature, many techniques are proposed to achieve better performance of the PV-grid system. A coordinated control [14] is used to reduce the output variation. In [15], with a nonlinear command, the THD reaches 2.44%.…”
Section: Introductionmentioning
confidence: 99%