Coolerado and Modeling an Application of the Maisotsenko Cycle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 0 publications
1
12
0
Order By: Relevance
“…In this section, a validation study was conducted comparing the current numerical work with the experimental results [22] of an HMX manufactured by Coolorado Corporation [43]. The operating and geometric conditions for the experimental results of [22] are given in Table 3. Table 3.…”
Section: Comparison With An M50 Air Cooler [43] (Part I)mentioning
confidence: 99%
See 2 more Smart Citations
“…In this section, a validation study was conducted comparing the current numerical work with the experimental results [22] of an HMX manufactured by Coolorado Corporation [43]. The operating and geometric conditions for the experimental results of [22] are given in Table 3. Table 3.…”
Section: Comparison With An M50 Air Cooler [43] (Part I)mentioning
confidence: 99%
“…Parameters Quantity Units Additionally, the details of the instrumentation utilized in the experimental testing of [22] are shown in Table 4. Table 4.…”
Section: Nomentioning
confidence: 99%
See 1 more Smart Citation
“…• Data center AC [11,13,35] • Turbine inlet air cooling [25,36,37] • Museum AC [15,16,38,39] • Ships and marine AC [40,41] • Storage of machinery, pharmacy, artifact, and electronic devices [42] Lots of research have been conducted worldwide in order to establish low-cost energy-efficient AC system for above-mentioned AC applications. Therefore, many systems have been resulted suitable depending upon the nature of AC application, availability of low-cost energy type, economics, efficiency, and sustainability.…”
Section: Miscellaneous Applicationsmentioning
confidence: 99%
“…As figure 1 illustrates it indirect evaporative cooling system provides desired cooling condition without moisture. Due to high efficiency of the M-cycle the greenhouse emissions will be decreased [4] and this process is more economic in comparison with traditional methods of cooling system [5,6]. The maximum exergy loss occurs at 0˚C and it will reach the minimum at higher temperatures [7] so the M-cycle is more efficient when used in hot and dry climates.…”
Section: Introductionmentioning
confidence: 99%