Coolant temperature distribution in the model of the fuel assembly peripheral area
Pavel Lobanov,
Aleksandr Svetonosov
Abstract:To evaluate the interchannel temperature transfer, the test section was created, the working section of which is a model of two neighboring cells of the peripheral region of the fuel assembly. The experimental setup is equipped with three fuel rod simulators 500 mm long. During the work, the fuel rods were connected in turn to the power source. This made it possible to determine the features of the temperature distribution in the model with uneven energy release. The power of each fuel rod simulator was up to … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.