2015
DOI: 10.1177/1932296815598775
|View full text |Cite
|
Sign up to set email alerts
|

Cook and Chill

Abstract: Compensating technologies embedded within blood glucose monitoring systems studied here perform well at extreme temperatures. People with diabetes need to be alerted to this feature to avoid perceptions of malperformance of their devices and the possible inability to get blood glucose readings on short notice (eg, during time of suspected rapid change or before an unplanned meal).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 11 publications
(12 reference statements)
0
3
0
Order By: Relevance
“…All measurements were performed in a controlled environment with a certain temperature and humidity as required in ISO 15197. These conditions do not reflect real-world usage and it is well known that environmental conditions can affect analytical performance [ 22 , 23 ]. Regarding user performance evaluation, it would be valuable to see whether training of the subjects would lead to a significant reduction of handling errors.…”
Section: Discussionmentioning
confidence: 99%
“…All measurements were performed in a controlled environment with a certain temperature and humidity as required in ISO 15197. These conditions do not reflect real-world usage and it is well known that environmental conditions can affect analytical performance [ 22 , 23 ]. Regarding user performance evaluation, it would be valuable to see whether training of the subjects would lead to a significant reduction of handling errors.…”
Section: Discussionmentioning
confidence: 99%
“…Differences in sensitivity and specificity may be attributed to different temperatures in our and other studies. It has been shown that when POC devices and strips are exposed to temperatures out of the range specified by the manufacturer, erroneous measurements might result (Nerhus et al, 2011;Deakin et al, 2015).…”
Section: Technical Notementioning
confidence: 99%
“…10 Glucose test strips of 5 test systems were kept at −5°C or at 50°C within 30 minutes had little effect on the glucose measurements when compared to those kept at room temperature. 11 Therefore, the performance of BG testing by glucose meter should be investigated under stressed environmental conditions to prevent potential adverse effects influencing clinical decisions making.…”
mentioning