2021
DOI: 10.3390/nano11020352
|View full text |Cite
|
Sign up to set email alerts
|

Conversion of Secondary C3-C4 Aliphatic Alcohols on Carbon Nanotubes Consolidated by Spark Plasma Sintering

Abstract: We analyze how the changes in the dimension of carbon nanomaterial (CNM) affect their catalytic conversion of secondary aliphatic alcohols. Carbon nanotubes (CNTs) consolidated by spark plasma sintering (SPS) were inactive in the conversion of secondary C3-C4 aliphatic alcohols because of the «healing» of defects in carbon structure during SPS. Gas-phase treatment of consolidated CNTs with HNO3 vapors led to their surface oxidation without destruction of the bulk structure of pellets. The oxygen content in con… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
0
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 67 publications
0
0
0
Order By: Relevance
“…According to XPS data, the content of sp 3 -hybridized carbon atoms and carbon-oxygen bonds increased with the increase of oxidation duration (Figure 4c). We have also previously shown that an increase in the oxidation time of CNTs and CNFs, as well as consolidated and oxidized CNTs and CNFs, leads to an increase in oxygen groups and surface defectiveness according to Raman spectra [71] and, at the same time, the number of paramagnetic centers [25,28,29,31,48,49].…”
Section: Resultsmentioning
confidence: 84%
See 3 more Smart Citations
“…According to XPS data, the content of sp 3 -hybridized carbon atoms and carbon-oxygen bonds increased with the increase of oxidation duration (Figure 4c). We have also previously shown that an increase in the oxidation time of CNTs and CNFs, as well as consolidated and oxidized CNTs and CNFs, leads to an increase in oxygen groups and surface defectiveness according to Raman spectra [71] and, at the same time, the number of paramagnetic centers [25,28,29,31,48,49].…”
Section: Resultsmentioning
confidence: 84%
“…All observed spectra are well fitted with two Lorentzian lines with different widths corresponding to gland gh-factors and located at low-and high-applied fields, respectively (Figure 6b,d,f,h). Therefore, we consider two types of paramagnetic centers attributed to these lines [29,49]. Figure 6.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations