2014
DOI: 10.1016/j.electacta.2014.06.053
|View full text |Cite
|
Sign up to set email alerts
|

Controllable synthesis of multi-walled carbon nanotubes/poly(3,4-ethylenedioxythiophene) core-shell nanofibers with enhanced electrocatalytic activity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
8
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 37 publications
2
8
0
Order By: Relevance
“…42−44 The existence of PEDOT was evidenced by the peak of COC bond deformation at 437 cm −1 , OCC deformation at 848 cm −1 , oxyethylene ring deformation at 988 cm −1 , asymmetric CC stretching pattern at 1502 cm −1 and symmetric CC stretching at 1432 cm −1 . 45,46 The above results about the PEDOT wrapping layer are in accordance with the FT-IR data in Figure 5b. To be specific, vibration bands at 1143 and 1090 cm −1 corresponding to the COC stretching confirmed the existence of ethylene dioxy group.…”
Section: ■ Results and Discussionsupporting
confidence: 87%
“…42−44 The existence of PEDOT was evidenced by the peak of COC bond deformation at 437 cm −1 , OCC deformation at 848 cm −1 , oxyethylene ring deformation at 988 cm −1 , asymmetric CC stretching pattern at 1502 cm −1 and symmetric CC stretching at 1432 cm −1 . 45,46 The above results about the PEDOT wrapping layer are in accordance with the FT-IR data in Figure 5b. To be specific, vibration bands at 1143 and 1090 cm −1 corresponding to the COC stretching confirmed the existence of ethylene dioxy group.…”
Section: ■ Results and Discussionsupporting
confidence: 87%
“…8 only one oxidation peak was observed at 0.511 V without any reduction peak in the reverse scanning. This phenomenon is well consist with previous reports [47,48], and mechanism for the electrochemical oxidation of magnolol at the GrO-COO-Poly-IL/GCE can be proposed as Scheme 1 (II).…”
Section: Effects Of Scan Ratesupporting
confidence: 62%
“…PEDOT functionalized materials are widely used as electrochemical sensors (Nie et al 2013; Zhang et al 2014; Zhang et al 2015). In particular, PEDOT/GO and its PEDOT/reduced GO counterpart have been shown to be effective for the selective chemical sensing of DA on 3mm diameter glassy carbon macroelectrodes using conventional cyclic voltammetry (100 mV/s sweep rate) (Wang et al 2014; Weaver et al 2014b).…”
Section: Introductionmentioning
confidence: 99%