2020
DOI: 10.3390/en13153967
|View full text |Cite
|
Sign up to set email alerts
|

Control System Development for the Three-Ports ANPC Converter

Abstract: This paper proposes a control system for the single-phase Three-Ports Active Neutral- Point-Clamped (ANPC-3P) converter, which can inject a sinusoidal current into the grid, balance the neutral point voltage, and regulate the energy storage system (ESS) current with reduced low-frequency ripple. Despite other applications, ANPC-3P inverter can be used in grid-tied renewable generation to allow the simultaneous connection of a photovoltaic (PV) energy source and an ESS to the AC grid. The ESS is connected direc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 33 publications
0
4
0
Order By: Relevance
“…Basically, the amplitude of the dc-link voltage is dynamically modified, while the PV-string is not generating its maximum energy. In [48], a topology was introduced, denominated as an active NPC inverter. Such topology allows the interface of an ESS to be directly connected to the dc-link voltage, also eliminating the MPPT converter.…”
Section: Hybrid Pv-ess Systems For Improving Power Quality and Grid R...mentioning
confidence: 99%
“…Basically, the amplitude of the dc-link voltage is dynamically modified, while the PV-string is not generating its maximum energy. In [48], a topology was introduced, denominated as an active NPC inverter. Such topology allows the interface of an ESS to be directly connected to the dc-link voltage, also eliminating the MPPT converter.…”
Section: Hybrid Pv-ess Systems For Improving Power Quality and Grid R...mentioning
confidence: 99%
“…The control of the energy flow of DER can be performed by various isolated converters dedicated to each energy device or through a multiport converter. For technical and economic reasons multiport converters have some advantages over isolated ones, they present less complexity when controlling the entire system and they do not require communication between devices, making possible the centralization of energy management while reducing the number of system's controllers [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Finally, when a comparison with MMC-based systems [13] is considered, ANPC converters seem more appropriate, as MMC introduces a bulkier structure, and adds further complexity to the system [8]. Furthermore, ANPC systems were positively verified in terms of both three-wire [14] and EV charging systems [15].…”
Section: Introductionmentioning
confidence: 99%