2016
DOI: 10.11591/ijeei.v4i1.197
|View full text |Cite
|
Sign up to set email alerts
|

Control of Wind Energy Conversion System and Power Quality Improvement in the Sub Rated Region Using Extremum Seeking

Abstract: For the purpose of better utilization and to have control over varying wind speeds we use variable speed wind turbines. The performance mainly depends on the system operating point. In this paper we implement extremum seeking (ES) which is a non-model based approach for maximum power extraction in the region between cut-in speed and rated speed. The convergence of the system depends mainly on the system dynamics so we go for non-linear control based on field oriented approach and also feedback linearization. F… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 18 publications
(19 reference statements)
0
5
0
Order By: Relevance
“…20. From (10), it can be interpreted that the output power depends on the TSR and pitch angle, i.e. λ and β, respectively.…”
Section: Deloading Mpp Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…20. From (10), it can be interpreted that the output power depends on the TSR and pitch angle, i.e. λ and β, respectively.…”
Section: Deloading Mpp Controlmentioning
confidence: 99%
“…To achieve this objective, a controller is needed for tracking the maximum peak power irrespective of the wind speed. Most often this MPPT algorithm is operated when the wind speed is in the range of V cut_in and V rated [9,10].…”
Section: Introductionmentioning
confidence: 99%
“…The impact of wind has made many researchers to find an optimum solution for integrating into the grid.The mechanical power w P [20,28,30] generated from the wind turbine is given by the expression, 32 0.5 ,…”
Section: Wind Energy Conversion System Modeling and Controller Dementioning
confidence: 99%
“…The SAP Filter based on the VSI topology is connected through the capacitor which delivers the supply for the compensation of the current harmonics in distribution system. The Total Harmonics Distortion (THD) [15][16][17][18] has the acceptable limit for both voltage and current. The THD of instantaneous current I1, I2, I3 up to In is given by square root of the mean (average) value of the squared function of the instantaneous values.The THD limit is 5% for Voltage and 8% for Current as per IEEE 519 standards.…”
Section: Introductionmentioning
confidence: 99%