2012
DOI: 10.1155/2012/259293
|View full text |Cite
|
Sign up to set email alerts
|

Control of Surge in Centrifugal Compressor by Using a Nozzle Injection System: Universality in Optimal Position of Injection Nozzle

Abstract: The passive control method for surge and rotating stall in centrifugal compressors by using a nozzle injection system was proposed to extend the stable operating range to the low flow rate. A part of the flow at the scroll outlet of a compressor was recirculated to an injection nozzle installed on the inner wall of the suction pipe of the compressor through the bypass pipe and injected to the impeller inlet. Two types of compressors were tested at the rotational speeds of 50,000 rpm and 60,000 rpm with the par… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 8 publications
(6 reference statements)
0
4
0
Order By: Relevance
“…. +1.5% +20% [200] 2012 Injection nozzle CC 2-11% ±0% +20% [176] 2007 Injection nozzle AC 0.15% +9% [176] 2007 Injection nozzle CC 0.9% +10% [201] 2005 Injection nozzle CC 0.9-4.6% ±0% ±0% [202] 2004 Injection nozzle CC 0.5% +25% [178] 2003 Injection nozzle CC 0.9% −1% +15% [178] 2003 Bleed control tube CC −5.5% +56%…”
Section: Injection Suction and Recirculationmentioning
confidence: 99%
See 1 more Smart Citation
“…. +1.5% +20% [200] 2012 Injection nozzle CC 2-11% ±0% +20% [176] 2007 Injection nozzle AC 0.15% +9% [176] 2007 Injection nozzle CC 0.9% +10% [201] 2005 Injection nozzle CC 0.9-4.6% ±0% ±0% [202] 2004 Injection nozzle CC 0.5% +25% [178] 2003 Injection nozzle CC 0.9% −1% +15% [178] 2003 Bleed control tube CC −5.5% +56%…”
Section: Injection Suction and Recirculationmentioning
confidence: 99%
“…Figure 12 shows a schematic view of the injection nozzle in the impeller inducer, where the high-momentum fluid is circulated from, e.g., the compressor outlet. Hirano et al [200] proposed that the optimum circumferential position for a single injector is on the opposite side of the volute tongue. For double injection, the optimum circumferential position for the first injection is between the volute tongue and the location at 30 • to the rotational direction when the second injection is located at 135 • from the tongue against the rotational direction, resulting in a 30% increase in surge margin [193].…”
Section: Injection Suction and Recirculationmentioning
confidence: 99%
“…In the best result they got, they reduced the minimum flow rate at which the compressor could operate by 10%. Hirano et al [8,9] carried out experiments to find the optimum circumferential location of air injection from the impeller inlet to extend the operating range of a centrifugal compressor. They found that the optimal position was on the opposite side of the volute tongue.…”
Section: Introductionmentioning
confidence: 99%
“…According to the mentioned sources, inlet distortion has adverse effects on the compressor performance, but different methods can be used to compensate for it. Some approaches to compressor performance improvement have been proposed in some studies (Stein et al 2000;Suder et al 2000;Iyengar et al 2005;Beheshti et al 2006;Khaleghi et al 2008a;Hirano et al 2012;Ma and Kim 2017;Yang et al 2017;Dong et al 2018;Taghavi-Zenouz and Behbahani 2018;Sun et al 2019;Li et al 2020;Li et al 2021;Wang et al 2021).…”
Section: Introductionmentioning
confidence: 99%