1980
DOI: 10.1016/0005-2736(80)90487-3
|View full text |Cite
|
Sign up to set email alerts
|

Control of membrane potential by external H+ concentration in Bacillus subtilis as determined by an ion-selective electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0

Year Published

1981
1981
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 18 publications
1
6
0
Order By: Relevance
“…Using this approach, we estimated the membrane potential of B. subtilis to reach ~ −110 mV under the growth conditions used in our experiments. This value is in good agreement with previously published estimates (Hosoi et al, 1980 ; Zaritsky et al, 1981 ).…”
Section: Resultssupporting
confidence: 93%
“…Using this approach, we estimated the membrane potential of B. subtilis to reach ~ −110 mV under the growth conditions used in our experiments. This value is in good agreement with previously published estimates (Hosoi et al, 1980 ; Zaritsky et al, 1981 ).…”
Section: Resultssupporting
confidence: 93%
“…[methoxy-14C]inulin (0.05 mCi/2.8 mg) was obtained from New England Nuclear Corp. TPP+ was purchased from Merck (Germany), and carbonyl cyanide-m-chlorophenyl hydrazone (CCCP) was a product of Tokyo Kasei Co. (Japan). Other chemicals used were described previously (9,28).…”
Section: Materlals and Methodsmentioning
confidence: 99%
“…Cell concentration was adjusted to an absorbancy at 590 nm of 4.0. TPP+ uptake by the cells was monitored with a TPP+-selective electrode at 30°C, and the AO\ was calculated as described previously (9).…”
Section: Measurement Of ['H]tpmp+ Uptake [3h]-mentioning
confidence: 99%
“…Bacteria were added to an OD 595 of 4.0 in 10 mL of the same buffer supplemented with glucose and TPP + to a concentration of 5 mM and 10 mM, respectively, and TPP + uptake was measured with the TPP + -selective electrode method described by Hosoi et al 46 TPP + concentration in the external medium was determined with a Kwik-Tip Ag/AgCl half-cell electrode, which was constructed according to the instructions provided by the manufacturer (World Precision Instruments, Sarasota, FL, USA). Both the TPP + -selective electrode and a Flexible Dri-Ref reference electrode (World Precision Instruments, Sarasota, FL, USA) were connected to a Jenway 3510 ion meter (Cole-Parmer, Staffordshire, UK) and the LabTrax 4-Channel Data Acquisition system (WPI).…”
Section: Qrt-pcrmentioning
confidence: 99%