2020
DOI: 10.1109/jestpe.2019.2941829
|View full text |Cite
|
Sign up to set email alerts
|

Control Design and Stability Analysis of Power Converters: The MIMO Generalized Bode Criterion

Abstract: Three-phase dynamic systems and multiphase generators are frequently modeled and controlled in the synchronous reference frame. To properly model the cross-coupling terms in this reference frame, complex vector theory and transfer function matrices are commonly applied, obtaining multipleinput multiple output (MIMO) dynamic models. The stability of MIMO systems can be assessed through the Nyquist Generalized Stability Criterion. However, the use of the Nyquist diagram complicates the controller design. The Bod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 33 publications
(17 citation statements)
references
References 32 publications
0
17
0
Order By: Relevance
“…When there are poles at z = −1, L(z) cannot be evaluated at ω = ω N = π/T s , and the original Nyquist contour z = exp(jωT s ) must be modified [17], [58]. In order to exclude these poles, the contour is indented around z = −1 as z = −1 + ε•exp(jϕ), with ε positive and sufficiently small, and ϕ increasing from π/2 to 3π/2.…”
Section: Equivalence Between Bode and Nyquist Diagrams Of An Open-loomentioning
confidence: 99%
“…When there are poles at z = −1, L(z) cannot be evaluated at ω = ω N = π/T s , and the original Nyquist contour z = exp(jωT s ) must be modified [17], [58]. In order to exclude these poles, the contour is indented around z = −1 as z = −1 + ε•exp(jϕ), with ε positive and sufficiently small, and ϕ increasing from π/2 to 3π/2.…”
Section: Equivalence Between Bode and Nyquist Diagrams Of An Open-loomentioning
confidence: 99%
“…Impedance matrices are used to model the different components, as they are a straightforward approach to model the cross-coupling terms between both axis. Moreover, this modeling methodology can be used for symmetric and non-symmetric systems [20], [23], as the ones obtained when the power control loops and the PLL effect cannot be neglected for the stability analysis.…”
Section: System Modeling and Stability Analysis A System Descripmentioning
confidence: 99%
“…To analyze the system stability, the MIMO Generalized Bode Criterion (MIMO GBC) is applied [23]. According to this criterion…”
Section: Stability Analysismentioning
confidence: 99%
See 2 more Smart Citations