2006
DOI: 10.1109/ias.2006.256767
|View full text |Cite
|
Sign up to set email alerts
|

Control and Performance of a Medium-Voltage Transformerless Cascade PWM STATCOM with Star-Configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
18
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 20 publications
0
18
0
Order By: Relevance
“…If v eonv is a positive voltage between the levels Vj and Vj+1 , then q1 = ... =qj =1 , qj+2 =···=q8 =0. Solving (6) and (7) with the description ofdiscrete-time variables, with the initial conditions ik and Vci(k)' i = 1, ...,8 , gives the approximate ac-side current ik+1 and capacitor voltages V c i(k+1) , i =1,...,8 at t =tk+1 as (8). Where (11) III.…”
Section: --Ts --Oj-z)/(e Rc V C J+1(k))mentioning
confidence: 99%
See 1 more Smart Citation
“…If v eonv is a positive voltage between the levels Vj and Vj+1 , then q1 = ... =qj =1 , qj+2 =···=q8 =0. Solving (6) and (7) with the description ofdiscrete-time variables, with the initial conditions ik and Vci(k)' i = 1, ...,8 , gives the approximate ac-side current ik+1 and capacitor voltages V c i(k+1) , i =1,...,8 at t =tk+1 as (8). Where (11) III.…”
Section: --Ts --Oj-z)/(e Rc V C J+1(k))mentioning
confidence: 99%
“…3) For the same power capability, the cascade converter requires less number of power components such as switches and diodes. The modulation methods presented for the cascade multilevel converter can be classified into staircase modulation [3]- [5], phase-shifted sinusoidal pulsewidth modulation [6]- [8] and multi-pulse optimal pulsewidth modulation [9], [10]. With the staircase modulation the converter switches operate at lower frequency.…”
mentioning
confidence: 99%
“…Cascaded multi-level converter has a lower output of waveform harmonic content, save more switching devices and has a more simple control system than other kinds of multi-level converter. Moreover its H-bridge modules have a compact structure, flexible configuration and reliable performance [8]- [10]. So the cascaded multi-level structure is used as converter topology of STATCOM in this paper.…”
Section: Introductionmentioning
confidence: 99%
“…There are a number of reasons for this, but the main one is that it is feasible to obtain a large number of levels with this topology [1], [2]. With alternative topologies the level numbers are constrained by component number and capacitor voltage balance issues [3]. The increased number of levels achievable with the H-bridge multi-level converter also allows greater switching redundancy, which creates more flexibility in terms of the ability to trade-off between harmonic performance, switching losses and voltage balancing.…”
Section: Introductionmentioning
confidence: 99%
“…Initially the desired output voltages for each phase are calculated in the dead-beat current controller. The 'MPC' block then evaluates the corresponding voltage vector for each switching combination using (3).…”
Section: Introductionmentioning
confidence: 99%