2020
DOI: 10.1002/2050-7038.12573
|View full text |Cite
|
Sign up to set email alerts
|

Control and analysis of a 3‐level diode‐clamped split source inverter in the applications of grid‐tied photovoltaic systems

Abstract: Back ground and Aim In this work, a new control scheme is developed to track the peak power from a solar energized grid‐tied three‐level diode‐clamped split source inverter (DCSSI). Material and method Two isolated photovoltaic sources (PV) are considered as sources for the topology. The impedance network serves as a voltage booster and enhances the input PV voltage. Two individual perturb and observe maximum power tracking algorithms are used to pursue the peak power and to generate two individual dc‐link vol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 27 publications
(31 reference statements)
0
3
0
Order By: Relevance
“…The expressions of current regulator loop can be represented as 55 Vd,conv=Ugd+rgId,refLgωIq,ref+Lgdigddt Vq,conv=Ugq+rgIq,ref+LgωIq,ref+Lgdigqdt, …”
Section: Proposed Control Scheme For Ssi‐based Wind Systemmentioning
confidence: 99%
“…The expressions of current regulator loop can be represented as 55 Vd,conv=Ugd+rgId,refLgωIq,ref+Lgdigddt Vq,conv=Ugq+rgIq,ref+LgωIq,ref+Lgdigqdt, …”
Section: Proposed Control Scheme For Ssi‐based Wind Systemmentioning
confidence: 99%
“…So, the dc‐link voltage should revert to the recommended voltage to transfer the maximum power. The recommended or reference value of the dc‐link voltage regulator is given as [23, 24] : Vdc,ref2Vabc,SSI6mabc,where Vabc,SSI is the rms voltage of SSI and mabc is the modulation index of SSI.…”
Section: Basic Principle Of Operation Of Ssi and Proposed Control Schemementioning
confidence: 99%
“…As a result, the dc-link voltage (CH3) experiences a voltage undershoot and returns to the reference value due to a well-tuned PI controller. The grid voltage (CH5) remained constant, but the grid current (CH6) experienced FIGURE 24 The dc-link voltage (V 2 ), two level voltage (V 3 ) and current (I 3 ), grid voltage (V 4 ) and current (I 4 ) at constant PV voltage (V 1 ) and current (I 1 ) for case-I as mentioned in Section 3 FIGURE 25 The effect of variable irradiance on the dc-link voltage regulator and current controller for case-I and case-II as mentioned in Section 3 a decreased magnitude. The zoomed version of the transient analysis is also presented in Figure 25.…”
Section: Experimental Analysismentioning
confidence: 99%