2018
DOI: 10.1148/radiol.2017172170
|View full text |Cite
|
Sign up to set email alerts
|

Contrast Media for Coronary CT Angiography: Should an Iso-osmolar Agent Be Used?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…A relatively high and uniform contrast attenuation (>250 HU) of the coronary arteries is required to reliably assess the severity of coronary artery stenosis using coronary CT angiography. 17 The luminal CT attenuations of the aortic root in coronary CT angiography reported from recent studies are 400 to 500 HU. 14,[18][19][20] However, in cardiac CT, sometimes the contrast enhancement is not as good as expected because of deteriorated cardiac function.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A relatively high and uniform contrast attenuation (>250 HU) of the coronary arteries is required to reliably assess the severity of coronary artery stenosis using coronary CT angiography. 17 The luminal CT attenuations of the aortic root in coronary CT angiography reported from recent studies are 400 to 500 HU. 14,[18][19][20] However, in cardiac CT, sometimes the contrast enhancement is not as good as expected because of deteriorated cardiac function.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, we conducted a phantom experiment to imitate coronary CT angiography in actual clinical practice. A relatively high and uniform contrast attenuation (>250 HU) of the coronary arteries is required to reliably assess the severity of coronary artery stenosis using coronary CT angiography 17 . The luminal CT attenuations of the aortic root in coronary CT angiography reported from recent studies are 400 to 500 HU 14,18–20 .…”
Section: Discussionmentioning
confidence: 99%
“…The demand for homogeneous and high-vascular contrast enhancement is critical for CTA to provide an appropriate interpretation of abnormal vascular findings (1,2). Coronary artery enhancement at a CT attenuation above 250 Hounsfield units (HU) is suggested for evaluating atherosclerotic changes and stenosis in coronary CTA (3). Generally, vascular enhancement is determined by scanning acquisition and reconstruction parameters (scan duration, tube voltage, and tube current), patient-related factors (heart rate, body weight, and cardiac output), injection rate, and contrast media concentration (4)(5)(6).…”
Section: Introductionmentioning
confidence: 99%