2010
DOI: 10.1016/j.acra.2010.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Contrast-Enhanced Whole-Heart Coronary MRA using Gadofosveset

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 35 publications
1
8
0
Order By: Relevance
“…This study of coronary MRA at 3.0T was designed as an intra-individual comparison between gadofosveset trisodium, an intravascular contrast agent, and gadobenate dimeglumine, an extracellular chelate. In summary, gadofosveset had superior image quality and CNR compared with gadobenate for coronary MRA at 3T, corroborating with results seen in similar studies [19, 20]. Despite showing improvements, CNR between the coronary arteries and the myocardium was still not significantly greater for gadofosveset over gadobenate.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…This study of coronary MRA at 3.0T was designed as an intra-individual comparison between gadofosveset trisodium, an intravascular contrast agent, and gadobenate dimeglumine, an extracellular chelate. In summary, gadofosveset had superior image quality and CNR compared with gadobenate for coronary MRA at 3T, corroborating with results seen in similar studies [19, 20]. Despite showing improvements, CNR between the coronary arteries and the myocardium was still not significantly greater for gadofosveset over gadobenate.…”
Section: Discussionsupporting
confidence: 87%
“…Nephrogenic systemic fibrosis (NSF) has been associated with gadolinium-based contrast agents in patients with renal dysfunction [19, 30]. Metabolic acidosis, caused by disassociation of free Gd 3+ ions, is known to be a significant cause of renal failure and NSF [31].…”
Section: Discussionmentioning
confidence: 99%
“…Recently, 3T MRI has also been made available in the clinical setting (15). A field strength of 3T offers a higher signal-to-noise ratio and contrast-to-noise ratio than 1.5T, which improves the image quality (31). Therefore, 3T MRI may achieve better diagnostic performance than 1.5T MRI.…”
Section: Discussionmentioning
confidence: 99%
“…The agent reversibly binds to albumin, yielding a higher relaxivity as well as prolonged blood pool residence [7]. Initial work exploring the use of this agent for cardiac imaging was focused on the adult population [811] with promising results. More recently, evaluation in children has focused on enhancing bright blood balanced steady state imaging, also with promising results [12].…”
Section: Introductionmentioning
confidence: 99%