“…In contrast to prior studies where MP was estimated over a subjectively selected region of interest using CEUS, our study used a custom-designed algorithm, which provided high-resolution MP estimation based on plateau image intensity data (18)(19)(20)(21)(22)(23). The high-resolution, pixel-by-pixel parametric perfusion maps indicated subtle, regional dysfunction in graft perfusion earlier than seen with histology, suggesting that the method can be used as a truly early diagnostic modality.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In contrast to prior studies where MP was estimated over a subjectively selected region of interest using CEUS, our study used a custom-designed algorithm, which provided high-resolution MP estimation based on plateau image intensity data (18)(19)(20)(21)(22)(23). The high-resolution, pixel-by-pixel parametric perfusion maps indicated subtle, regional dysfunction in graft perfusion earlier than seen with histology, suggesting that the method can be used as a truly early diagnostic modality.…”
Section: Discussionmentioning
confidence: 99%
“…The transducer position was fixed using a mechanical positioning system. Nonlinear contrast imaging was performed with a smallanimal ultrasound scanner (Vevo 2100; VisualSonics, Toronto, ON, Canada) using a broadband linear transducer array (13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24) MHz, MS250, VisualSonics). B-mode images were used to initially locate the graft and to optimally position the transducer over the imaging plane.…”
Section: Ceus Imaging Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…These intensities were then fitted ( Y = Y 0 + ( A − Y 0 )·(1 − exp (− β · x ) )) for calculation of microvascular blood volume A and the microvascular filling velocity β , which corresponds to the capillary blood exchange rate. The estimate of perfusion was calculated as the product of A and β [ 23 ].…”
Section: Methodsmentioning
confidence: 99%
“…As previously described, transthoracic myocardial contrast echocardiography (MCE) was performed using an iE33 ultrasound scanner equipped with a S5 – 1 transducer (Philips Medical Systems, Best, The Netherlands) [18]. A contrast agent consisting of microbubbles filled with sulphur hexafluoride with a mean diameter of 2,5 μm was used (Sonovue, Bracco Imaging, Milan, Italy) and continuously infused using a specific syringe pump (VuEject, Bracco SA, Switzerland).…”
Section: Methodsmentioning
confidence: 99%