2005
DOI: 10.1002/jmri.20256
|View full text |Cite
|
Sign up to set email alerts
|

Contrast‐enhanced magnetic resonance angiography of the lower extremities: Standard‐dose vs. high‐dose gadodiamide injection

Abstract: Purpose:To compare the efficacy and safety of two different doses (0.1 and 0.3 mmol/kg of body weight [BW]) of gadodiamide for contrast-enhanced magnetic resonance angiography (ce-MRA) of the lower extremities with intraarterial digital subtraction angiography (IA-DSA). Materials and Methods:A total of 30 patients with peripheral arterial occlusive disease underwent IA-DSA and ce-MRA from the aortic bifurcation down to the ankle. Patients were randomized to receive a total dose of 0.1 or 0.3 mmol/kg of BW gado… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
1
2

Year Published

2006
2006
2014
2014

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(17 citation statements)
references
References 26 publications
0
14
1
2
Order By: Relevance
“…However, a drawback of contrast-enhanced MR angiography is insuffi cient contrast enhancement for accurate visualization and diagnosis if the contrast agent dose is too low (6)(7)(8)(9). This is particularly relevant in the peripheral runoff vasculature where vessels are smaller and highly susceptible to fl ow alterations in heavily diseased patients; it is also relevant if parallel imaging techniques are used because these techniques decrease the signal-to-noise ratio (SNR) ( 10 ).…”
Section: Patientsmentioning
confidence: 99%
“…However, a drawback of contrast-enhanced MR angiography is insuffi cient contrast enhancement for accurate visualization and diagnosis if the contrast agent dose is too low (6)(7)(8)(9). This is particularly relevant in the peripheral runoff vasculature where vessels are smaller and highly susceptible to fl ow alterations in heavily diseased patients; it is also relevant if parallel imaging techniques are used because these techniques decrease the signal-to-noise ratio (SNR) ( 10 ).…”
Section: Patientsmentioning
confidence: 99%
“…For evaluation of each vascular region, we used three-dimensional (3-D) fast spin echo (FSE) T1-weighted sequences with the following parameters: TR= 6 ms, TE 1.5 ms, flip angle 35°, slice thickness 1.5 mm (3 mm with 1.5-mm overlap), field of view 430 mm, matrix 512×512, number of slices 70 and acquisition time 28 s. Overall acquisition time of successive sequences, including the time needed for two table moveIntroduzione L'angiografia mediante risonanza magnetica (Angio-RM) ha trovato negli ultimi anni applicazione sempre più ampia nella valutazione delle arteriopatie degli arti inferiori. I progressi tecnologici hanno fatto sì che tale indagine possa garantire una sensibilità ed una specificità elevate, utilizzando l'angiografia digitale come gold standard, pur se i lavori pubblicati riportano un range di percentuali assai ampio (sensibilità tra il 71% e il 100%, specificità tra il 63% e il 100%) [1][2][3][4][5][6][7][8][9][10][11]. Molti lavori hanno preso quindi in considerazione il suo apporto diagnostico ed hanno sottolineato i suoi benefici, per il trascurabile costo biologico.…”
Section: Examination Techniqueunclassified
“…Technological advancements have allowed this technique to provide high levels of sensitivity and specificity as compared with digital subtraction angiography (DSA) as the gold standard even though the reported ranges are extremely wide (sensitivity: 71%-100%, specificity: 63%-100%) [1][2][3][4][5][6][7][8][9][10][11]. Most papers have, therefore, considered its diagnostic contribution and emphasised its advantages of having a negligible biological cost.…”
Section: Introductionmentioning
confidence: 99%
“…Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been shown to be a very useful diagnostic tool in the detection and evaluation of many breast diseases (1)(2)(3)(4). The use of fat suppression is recommended for sequences that are used for assessment of contrast enhancement (5).…”
Section: Introductionmentioning
confidence: 99%