2018
DOI: 10.1016/j.optcom.2018.06.011
|View full text |Cite
|
Sign up to set email alerts
|

Continuous-wave off-axis and in-line terahertz digital holography with phase unwrapping and phase autofocusing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 35 publications
0
12
0
Order By: Relevance
“…The epidermis and dermis skin tissues could be distinguished from the amplitude image, and the difference of the optical path length at different positions of the tissue could be obtained from the phase information. In 2018, Huang et al presented and investigated the off-axis CW TDH based on the 2.52 THz FIRL 100 and a Pyrocam III (240 × 240 pixels) detector to image an asparagus fern [68]. The autofocus algorithm was used to find the amplitude reconstruction distance of 51.52 mm, and the phase reconstruction distance was 52.29 mm.…”
Section: Cw Thz Digital Holographymentioning
confidence: 99%
“…The epidermis and dermis skin tissues could be distinguished from the amplitude image, and the difference of the optical path length at different positions of the tissue could be obtained from the phase information. In 2018, Huang et al presented and investigated the off-axis CW TDH based on the 2.52 THz FIRL 100 and a Pyrocam III (240 × 240 pixels) detector to image an asparagus fern [68]. The autofocus algorithm was used to find the amplitude reconstruction distance of 51.52 mm, and the phase reconstruction distance was 52.29 mm.…”
Section: Cw Thz Digital Holographymentioning
confidence: 99%
“…Chen et al developed a denoising method for THz in-line digital holographic reconstructions, based on a Markov chain Monte Carlo sampling [151]. Different auto-focusing algorithms and corrections were investigated by Huang et al [125,127] and applied to reconstruct a pair of objects at different distances from the detector [121].…”
Section: In-line Digital Holographymentioning
confidence: 99%
“…It has serious implications for imaging, especially computational imaging experiments. For example, in the terahertz Fresnel off-axis digital holography experiment [1], the uneven intensity distribution of the light source seriously affects the accuracy of phase measurement. In the terahertz diffraction tomography [2], the uneven intensity distribution of the light source affects the fidelity of imaging.…”
Section: Introductionmentioning
confidence: 99%