2014
DOI: 10.1007/s00216-014-7786-8
|View full text |Cite
|
Sign up to set email alerts
|

Continuous vs. segmented second-dimension system gradients for comprehensive two-dimensional liquid chromatography of sugarcane (Saccharum spp.)

Abstract: A comprehensive two-dimensional liquid chromatography system in combination with photodiode array and mass spectrometry detection was developed for analysis of polyphenols in sugarcane (Saccharum spp.) leaf extracts. To achieve this, a micro cyano column and a partially porous octodecylsilica column were used in the first and the second dimension, respectively. The choice of the cyano column over other reversed-phase columns tested for the first-dimension separation was due to its lower correlation selectivity… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 35 publications
(26 citation statements)
references
References 40 publications
0
23
0
Order By: Relevance
“…The unique performance of these particle columns, offering the advantages of higher efficiencies and rugged design, capable of high-pressure operation, was demonstrated in some studies Marchetti et al, 2007;Cavazzini et al, 2007;Cunliffe and Maloney, 2007;Donato et al, 2009). Because of these attributes, these columns were chosen as 2 D of LC Â LC systems, and several research groups (Mondello, Dugo, Jandera and Cifuentes) used them in natural products applications (Hajek et al, 2008;Dugo et al, 2008cDugo et al, , 2009aRusso et al, 2011;Mondello et al, 2011;Cacciola et al, 2012;Leme et al, 2014;Jandera, 2012;Cesla et al, 2009;Hájek and Jandera, 2012;Montero et al 2013aMontero et al ,b, 2014Montero et al , 2016aDonato et al, 2016). In two of the abovementioned references (Dugo et al, 2008c;Hajek et al, 2008) the performance of a partially porous short column was compared with that of a monolithic column.…”
Section: Advances In Practicementioning
confidence: 99%
See 3 more Smart Citations
“…The unique performance of these particle columns, offering the advantages of higher efficiencies and rugged design, capable of high-pressure operation, was demonstrated in some studies Marchetti et al, 2007;Cavazzini et al, 2007;Cunliffe and Maloney, 2007;Donato et al, 2009). Because of these attributes, these columns were chosen as 2 D of LC Â LC systems, and several research groups (Mondello, Dugo, Jandera and Cifuentes) used them in natural products applications (Hajek et al, 2008;Dugo et al, 2008cDugo et al, , 2009aRusso et al, 2011;Mondello et al, 2011;Cacciola et al, 2012;Leme et al, 2014;Jandera, 2012;Cesla et al, 2009;Hájek and Jandera, 2012;Montero et al 2013aMontero et al ,b, 2014Montero et al , 2016aDonato et al, 2016). In two of the abovementioned references (Dugo et al, 2008c;Hajek et al, 2008) the performance of a partially porous short column was compared with that of a monolithic column.…”
Section: Advances In Practicementioning
confidence: 99%
“…Another type of gradient profile (called segmented in fraction (SIF)) was more recently investigated and applied to antioxidant analysis, and it will be described in Section 5.3 (Leme et al 2014). Nevertheless, such optimization strategies will likely be a very fruitful area of research as soon as they are implemented for the analysis of more sample types.…”
Section: Advances In Practicementioning
confidence: 99%
See 2 more Smart Citations
“…The coupling of similar columns (e.g., RP-LC×RP-LC) may offer superior resolution [13,14] when different mobile phase pH values [15][16][17] are utilized. This may also be implemented by varying the gradient composition between subsequent 2 D runs [18], according to the properties of the analytes being separated.…”
Section: Introductionmentioning
confidence: 99%